CobraNet Connection
Use a CobraNet interface card such as the MY16-CII to make CobraNet connections between the
digital mixer and DME units. Use an Ethernet cable connected to the [NETWORK] connectors to make
connections between DME series units. The port to be used for head amp control is specified via the
[Internal HA Control] parameter in the “Misc” tab in the “Utility” dialog box (page 166). Select “Slot 1”
when the DME unit to be used for serial communication is a DME24N, “Slot 1” through “Slot 4” if it is a
DME64N, or “CobraNet” if it is a DME Satellite unit. The settings for all other DME units should be
“OFF”.
It is also necessary to match the CobraNet serial communication channels of the interface card
installed in the serially connected DME unit with that of the interface card in the digital mixer. Refer to
page 480 for DME8i-C/8o-C/4io-C information. Refer to the CobraNet Manager Lite for Yamaha
Owner’s Manual for more information on setting the MY16-CII. Set the serial channel for all other
devices to “OFF”.
NOTE
As of July 2008 only the LS9 is the only digital mixer that supports CobraNet connection.
When two MY16-CII or similar CobraNet interface cards are installed in an LS9-32 in order to control multiple DME
units, use the COMM PORT parameter in the LS9 EXTERNAL HA display to select the slot to be used.