Operation Manual
DGX-620/520, YPG-625/525 Owner’s Manual 61
Backup and Initialization
The following settings are always backed up, and are maintained even when the power is turned off. If you
want to initialize the settings, use the Initialize operation as explained below.
Initialization. This function erases all backup data in the instrument’s flash memory and restores the initial
default settings. The following initialization procedures are provided.
■Backup Clear ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
To clear data backed up to the internal flash memory—panel user set-
ting, registration memory, user songs, style file—turn the power on by
pressing the [STANDBY/ON] switch while holding the highest white
key on the keyboard. The backed up data will be erased and the default
values restored.
■Flash Clear ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
To clear song data and style files that have been transferred to the inter-
nal flash memory from a computer, turn the power on by pressing the
[STANDBY/ON] switch while simultaneously holding the highest
white key on the keyboard and the three highest black keys.
● The Backup Parameters
• User Songs
• Style Files
•Registration Memory
• FUNCTION Settings: Tuning, Split Point, Touch Sensitivity, Style Volume, Song Volume,
Metronome Volume, Grade, Demo Cancel, Language Selection,
Panel Sustain, Master EQ type, Chord Fingering
Backup
Initialization
• When you execute the Flash
Clear operation, song data
you have purchased will also
be cleared. Be sure to save
data you want to keep to a
computer.
CAUTION