Supplementary Manual
Table Of Contents
Grouping and linking
V2.0 Supplementary Manual
5
Grouping and linking
DCA Roll-out function
You can now access all of the channels assigned to a DCA group simultaneously through the fader
banks.
This function enables flexible fader operations. For example, while controlling the DCA fader in the
Centralogic section, you can use the Roll-out function to access (roll-out) and control the faders
(assigned to the corresponding DCA group) through the fader bank located to the left of the
Centralogic section. Alternatively, you can control the faders rolled out to the Centralogic section via
DCA Roll-out, while operating the DCA faders through the fader bank on the left.
■ DCA Roll-out operation
1. Use a bank select key to select the DCA group that you want to control, then press
the [SEL] key for that DCA group.
DCA Roll-out mode is engaged, and the faders that have been assigned to the DCA group will be
rolled out.
2. If you press the [SEL] key for another DCA group, faders that have been assigned
to that DCA group will be rolled out.
3. Press the same [SEL] key again to exit DCA Roll-out mode.
NOTE
• You cannot turn Roll-out mode on while operating the DCA group (for example, while assigning
channels or editing the group name).
• Even if Roll-out mode is turned on while you are controlling a GEQ via faders, you cannot edit
the DCA group using the faders.
• If the number of channels assigned to a DCA group exceeds the number of faders in the block
(that is a roll-out target), you will be unable to control extra channels.
• All bank select keys in the block (to which the displayed channels belong) will light up.
• If the faders are rolled out to the Centralogic section (block B), the IN/OUT select keys in the
Centralogic section will be disabled.
• Bank select keys in blocks in which no faders are rolled out will operate normally.
■ Setting the DCA Roll-out function
1. In the Function Access Area, press the CH JOB button.
2. Press the DCA GROUP button to access the DCA/MUTE
GROUP ASSIGN MODE popup window.
3. Press the DCA ROLL-OUT button.
DCA GROUP
button
DCA ROLL-OUT
button