Yale Assure Lock Touchscreen Deadbolt Installation and Programming Instructions (YRD226/YRD620) ® ® This manual will walk you through all the required steps to add your new Yale Assure Lock to your door.
What's In The Box Optional Yale Smart Module Let's Get Started Keys Installation Guide Envelope (Includes this manual and door checker with template) Optional Fire Kit Parts Touchscreen Keypad Loosen screw to remove cover Battery Cover Inside Lock Assembly (Separates into 3 components) Inside Lock Mounting Plate 4 AA Batteries Mounting Hardware The mounting hardware box includes 12 components Strike Plate Adjustable Deadbolt Inside Lock Screws Strike Plate and Deadbolt Screws 2 P/N YRD226-MN
1 Removing Existing Door Hardware Do not discard old lock hardware until Assure Lock has been successfully installed.
2 Check Door Measurements and Make Adjustments If Needed Door Checker Use door checker from installation guide envelope to verify your door measurements and make any needed adjustments. Check Your Door Guide Let's Get Started New Door Marking Template With door checker, use template from installation guide envelope to prep a new door that has not been predrilled for hardware.
3 Installing Latch & Strike Plate *2-3/8" Backset default x2 Actual Size *Deadbolt latch position is based on backset. Choose position appropriate for your door. Reference Door Checker measurements E and F. *2-3/4" Backset x2 Actual Size O optional Pull x2 Bolt must be in retracted Press (unlocked) position. Actual Size Choose standard strike plate screws or security screws. Bolt must be in retracted (unlocked) position.
4 Installing Touchscreen Keypad Inside of Door Outside of Door O ! optional Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
5 Installing Inside Mounting Plate x2 Actual Size O optional 7 P/N YRD226-MNL-0001 Rev I
6 Attaching the Cable Assembly Ensure cable is securely fastened into adapter. ! Use cable hooks to ensure proper routing. Do not pinch wire.
7 Installing Inside Lock x3 Actual Size Ensure thumbturn is vertical. If the thumbturn does not move freely, refer to the hardware troubleshooting steps.
Testing Mechanical Operation ! Bolt must be in retracted (unlocked) position before installing AA batteries. ! If thumbturn operation fails, check the installation beginning with Step 7.
Testing Mechanical Operation ! 8 If key operation fails, check the installation beginning with Step 4. Installing Optional Yale Smart Module Inside of Door ! Batteries must not be installed prior to inserting and/or removing the Yale Smart module. For more information about Yale Smart modules and smart home features visit: https://www.yalehome.
9 Installing Batteries and Cover "Welcome to Yale Real Living" Tighten screw to replace cover ! Bolt must be in retracted (unlocked) position before installing batteries. Inside of Door Press the Yale logo to wake the lock. You will be guided to set up your lock by following the audio instructions on the lock. Additional entry codes and further programming can be done through the Settings Menu. Refer to page 15.
Using Your Lock Touchscreen Keypad Press to wake keypad or lock door Press to return to previous Settings Menu Press to enter or unlock Enter Master Entry Code and press to access Settings Menu Low Battery Indicator All Code Lockout Indicator Speaker Mechanical Key Backup Entry Method Inside Lock Battery Cover Speaker Inside Notification Light Privacy Button Thumbturn for manual locking and unlocking 13 P/N YRD226-MNL-0001 Rev I
1 Creating Master Entry Code The master entry code is used to change the lock settings. A security best practice is to set your master code with 6 or more digits and create a separate code that is used daily to lock and unlock the door. "Register Master Code. Press the gear key to continue." Press "Enter a 4 to 8 digit PIN code followed by the gear key." Enter 4-8 digit Master Entry Code "Registered.
2 Creating Entry Codes Master Entry Code must be created first. *Max user codes = 250 with Smart Module; 25 without. Enter Master Entry code "Menu Mode, press the gear key to continue.
3 Deleting Entry Codes Enter Master Entry Code Press Press Press "Menu Mode, enter number, press the gear key to continue." Press Press Deleting one entry code: To delete one entry code, you must enter the entry code you wish to delete.
4 Unlocking Door with Entry Codes Enter Entry Code Press 17 P/N YRD226-MNL-0001 Rev I
Setting Definitions Settings Default Setting Definition Creation required* The Master Entry Code is used for programming and for feature settings. It must be created prior to programming the lock. The Master code will also operate (unlock/lock) the lock. Auto Re-lock Disabled After a successful code entry or manual unlock with the key, the lock will automatically re-lock after each unlock in an effort to keep your home secure. This feature is optional, and can be turned off.
Customizing YRD226 Lock Through Settings Menu *Master Entry Code Required 1. Press Yale logo to wake up lock . 2. Enter Master Entry Code* followed by icon. Lock Response: "Welcome to the Settings Menu. Press each number to hear available settings and then press the settings icon to enter." 3. Enter digit corresponding to the function to be performed followed by the icon. Follow the voice commands.
Customizing YRD620 Lock Through Settings Menu *Master Entry Code Required 1. Press Yale logo to wake up lock . 2. Enter Master Entry Code* followed by icon. Lock Response: "Welcome to the Settings Menu. Press each number to hear available settings and then press the settings icon to enter." 3. Enter digit corresponding to the function to be performed followed by the icon. Follow the voice commands.
Troubleshooting Symptom • Suggested Action Yale keypad becomes active when the Yale logo is pressed. Verify contact with the logo. If keypad numbers are visible, check to see if they respond when pressed. Check batteries are installed and oriented correctly (polarity) in battery case. Check batteries are in good condition; replace batteries* if batteries are dead. Check to see if keypad cable is fully connected and is not pinched. Lock does not respond – door is open and accessible.
Hardware Troubleshooting Thumbturn Door Open Keypad Door Open If deadbolt does not extend or retract easily when testing thumbturn and keypad operation, revisit inside and keypad installation steps. It is important that the bolt be in the retracted position during lock installations and that installation procedure is followed carefully. Helpful Tip: Ensuring smooth deadbolt operation can enhance your battery life. Thumbturn Door Closed Test with door closed using thumbturn. Tab 2.
Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master Entry code*) are deleted and all programming features are reset to original default settings (see below). Reset Button 1. Remove the battery cover and batteries. 2. Remove the interior side of the lock to access the reset button. 3. The reset button (see image at right) is located beside the cable adapter. 4. While pressing the reset button (minimum of 3 seconds) reinstall batteries.
FCC: Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Yale Z-Wave Plus Smart Module Installation Guide ® ® ® Please use this procedure only when network primary controller is missing or otherwise inoperable. Adding a Yale Z-Wave Plus Smart Module to your Assure Lock & Z-Wave System ® 1.
! Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user's authority to operate the equipment. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.
Yale ZigBee Module Installation and Programming Instructions ® ® ® Installing the ZigBee® Module IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover. • Remove batteries. • Remove and/or insert network module. • Reinstall batteries. • Replace cover.
FCC: FCC ID: U4A-YRHCPZB0FM Model: YRMZB2 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.