Yale Real Living™ Push Button Deadbolt Installation and Programming Instructions NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For Technical Assistance call Yale at 1-800-810-WIRE (9473) This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com. Click “Product Information & Documentation” and then “Installation Instructions”.
TABLE OF CONTENTS Warnings...................................................................................................................... 2-3 Introduction......................................................................................................................3 Installation Components and Tools..............................................................................................4 Prepare Lock for Installation.........................................................................
Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
INSTALLATION COMPONENTS AND TOOLS Included in the box. . .
PREPARE LOCK FOR INSTALLATION Unpack the Lock The lock is packed representative of how it will install on the door. Before installing the lock on the door: A. Inside escutcheon 1. Loosen the screw (Phillips #2) holding the battery cover. (The screw remains attached to the battery cover) 2. Slide the battery cover up and out (note the two tabs at bottom of battery cover). 3. Remove the inside mounting plate (with gasket) from the back (door side) of the inside escutcheon.
INSTALL LOCK 1. Install bolt in door. 1 NOTE: The bolt must be in a retracted (unlocked) position when installing the lockset. Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied. (2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws 2. Install strike on the door frame, making sure to allow for the bolt to be centered in the strike. 2 (2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws 3. Install outside escutcheon.
CAUTION: Position and bend cable, using care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon. Label Use the cable hook (Note label on circuit board) as shown in Figures 6A & 6B to prevent binding when installing the escutcheon over the mounting plate. Figure 6A 6. Attach cable assembly connector to the inside escutcheon PC board by lining up notches on top of cable connector to slots on PCB connector (Fig. 6B).
. Install inside escutcheon on inside mounting plate. Note the horizontal orientation of the tailpiece (Fig. 7) as you insert the inside escutcheon (thumbturn should be vertical). Figure 7 9. Install and secure using (3) M4 x 8mm [8-32 x 5/16"] pan head screws through the inside escutcheon into the mounting plate (Fig. 8). (3) Pan head screws IMPORTANT: Before installing the batteries, test the mechanical operation of the lock by using both thumbturn and the key.
PROGRAMMING Programming Features-Menus-Keys-Definitions................................................ 9-10 Operation...........................................................................................................
Status Indicators 1 2 Low Battery Warning RED 3 Lock-out Mode RED & BLUE Enter the Menu Mode BLUE Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master)PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE (8 times); the keypad flashes as well. Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone playback for use in quiet areas.
OPERATION Register Master PIN Code Before Programming* 1. Press the key to enter Master PIN Code Registration. 2. Press the key followed by the key. 3. Enter a unique 4-8 digit Master PIN code followed by the 1 2 Press the key to enter Master Code Registration. key. 3 Press the "1" key followed by the . Enter the new Master PIN code (4~8 digits), followed by the key. PIN code structure Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes.
To reset the lock to factory default, see the following: Reset Lock to Factory Default The following procedure returns the lock to its factory defaults by deleting all user codes (including the Master PIN code*) and returning all programming features to their original default settings (see below). Reset Button Cable 1. Remove the batteries and then remove the interior escutcheon to access the reset button. 2. The reset button (see image at right) is located above the PCB cable connector. 3.
Open Door with PIN Code 1 2 3 Enter PIN code. Complete the code entry by pressing the key. Unlock. Privacy Mode vs. All Code Lockout Mode All Code Lockout is a Menu feature (6) that restricts Pin code access (except Master). Privacy mode is set by pressing and holding the privacy button (found below thumbturn) for a duration of four beeps. This deactivates the keypad and sound, and because it is set from the inside, provides a secure and silent lock for the convenience of the occupant(s).
Feature Programming Through Menu Mode Using Master PIN code* 1. Enter the 4-8 digit Master PIN code followed by the key. 2. Enter digit corresponding to the function to be performed followed by the key. Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
MISCELLANEOUS Hardware Troubleshooting.......................................................................................15 Programming Troubleshooting................................................................................16 Installing the Network Module ................................................................................17 Replace/Install Cylinder ..........................................................................................18 Sample Pin Code Management Sheets..........
Programming Troubleshooting Symptom Suggested Action Lock does not respond – door is open and accessible. • • • • Press each keypad button to see if they respond when pressed. Check batteries are installed and oriented correctly (polarity) in the battery case. Check batteries are in good condition; replace batteries* if discharged. Check to see if cable is fully connected and not pinched. Lock does not respond – door is locked and inaccessible.
Installing the Network Module IMPORTANT: The batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover • Remove batteries • Remove and/or insert network module • Reinstall batteries Use feature programming step 7 (page 12) for enrollment of the Network Module.
How to Replace or Install Cylinder 1. Remove cylinder: A A. Remove outside escutcheon from door. B. Remove rubber gasket. C. Remove two screws holding plastic guide in place. B D. Remove plastic guide. E. Remove screw with washer holding cylinder in place (visible after plastic guide is removed). F. Remove cylinder housing by pulling towards the door side of escutcheon. Before installing cylinder, please be sure you have correct length tailpiece. 2. Install new cylinder: A.
PIN CODE MANAGEMENT SAMPLE SHEETS PIN Code Management (No Network Module - Up to 25 Users) Location: User Type Door Number: User Name User # User User Name User # PIN Code PIN Code Master User 13 User 1 User 14 User 2 User 15 User 3 User 16 User 4 User 17 User 5 User 18 User 6 User 19 User 7 User 20 User 8 User 21 User 9 User 22 User 10 User 23 User 11 User 24 User 12 User 25 19 P/N AYRD210-INST-FUL Rev E An ASSA ABLOY Group brand
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries User Type User Name User # PIN Code User Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Us
ONLINE LITERATURE AND TEMPLATES For the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifications and installation instructions. Scan this code to view installation videos for this and other Yale Real Living products. Yale Locks & Hardware 100 Sargent Drive, New Haven, CT 06511 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.