Installation
External Power Connections
The FT-818 may be connected to an external 13.8 Volt DC power source providing at least
3 Amps of continuous-duty current.. The supplied E-DC-6 DC cable may be used for DC
connections.
While connected to an external DC source, if you have installed the supplied SBR-32MH
Ni-MH Battery Pack, the E-DC-6 connection to the external DC power source will allow op-
eration of the FT-818 while charging of the SBR-32MH is in progress.
When making DC power connections, be absolutely certain to follow the markings on the
E-DC-6 so as to ensure proper polarity of the connection to the power supply. Connect the
Red and Black or White and Black wire to the Positive (+) power supply terminal, and con-
nect the
Solid Black wire to the Negative (-) power supply terminal.
V A
0 05 510 2015 3020 40
CONTINU OUS CU RRENT 25A
OVE RLOA D
POW ER
ON
OFF
POWERSUPPLY
FP
-
1030
A
6A
25A 10A
FP-1030A
Supplied DC Cable (E-DC-6)
RED/BLACK
or
WHITE/BLACK
BLACK
GND
KEY DATA ACC
ANT
:
INPUT DC13.8V
INPUT DC13.8V
FT-818
Notice
Be extremely careful when making power supply connections. Use only a 13.8 Volt
DC Supply, and carefully observe the proper electrical polarity. Serious damage
may result if these precautions are not observed.
The Limited Warranty on this product does not cover damage caused by improper
power supply connections, or improper power supply voltage.
Important Note
Occasionally, the 430 MHz transmit signal may behave abnormally when the FT-
818 is operated using an External Power Supply and the whip antenna, especially
with the antenna in close proximity to surrounding metal objects.
If abnormal transmitter operation is ex-
perienced, wind one turn of the E-DC-
6 DC cable around the supplied ferrite
core, and snap its two halves together,
per the illustration below. Install the
core as close as possible to the DC
plug, as shown.
E-DC-6 DC Cable
as close as possible
wind one turn,
snap two halves