XDC 6000 Watt and 12000 Watt Series DigitalProgrammable DC Power Supply Operating Manual
SCPI Command Summary
TM-XDOP-01XN C–13
Table C-3
Commands for Output Control
Function SCPI Command Description Query
Set (Immediate)
Current Setpoint
[[:]SOURce][<channel>]:CURRent[:LEVel][:IMMediat
e][:AMPLitude] {<current>|MAXimum|MINimum}
Change current setpoint Yes
Set Triggered
Current Setpoint
[[:]SOURce][<channel>]:CURRent[:LEVel]:TRIGgered
[:AMPLitude] {<current>|MAXimum|MINimum|DEFault}
Change triggered current setpoint Yes
Set (Immediate)
Power Setpoint
[[:]SOURce][<channel>]:POWer[:LEVel][:IMMediate]
[:AMPLitude] {<power>|MAXimum|MINimum}
Change power setpoint Yes
Set Triggered
Power Setpoint
[[:]SOURce][<channel>]:POWer[:LEVel]:TRIGgered[:
AMPLitude] {<power>|MAXimum|MINimum|DEFault}
Change triggered power setpoint Yes
Set (Immediate)
Voltage Setpoint
[[:]SOURce][<channel>]:VOLTage[:LEVel][:IMMediat
e][:AMPLitude] {<voltage>|MAXimum|MINimum}
Change voltage setpoint Yes
Set Triggered
Voltage Setpoint
[[:]SOURce][<channel>]:VOLTage[:LEVel]:TRIGgered
[:AMPLitude] {<voltage>|MAXimum|MINimum|DEFault}
Change triggered voltage setpoint Yes
Set Voltage Slew
Rate Voltage
[[:]SOURce][<channel>]:VOLTage:SLEW:STEP{<slewra
te-voltage>|MAXimum|MINimum|DEFault}
Sets the voltage slew rate voltage
change for the programmed time
interval
Yes
Set Voltage Slew
Rate Interval
[[:]SOURce][<channel>]:VOLTage:SLEW:INTerval{<sl
ewrate-interval>|MAXimum|MINimum|DEFault}
Sets the voltage slew rate time
interval for the programmed
voltage change
Yes
Set Over Current
Protection Level
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
[:LEVel] {<current>|MAXimum|MINimum}
Set the over current protection
level
Yes
Set Over Current
Protection
Shutdown State
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
:STATe <on-off-state>
Select over current protection to
shutdown (ON) or set alarm
(OFF)
Yes
Query Over
Current Protection
Tripped
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
:TRIPped?
Query if over current protection
mechanism has tripped
N/A
Set Under Current
Protection Level
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer[
:LEVel] {<current>|MAXimum|MINimum}
Set under current protection level Yes
Set Under Current
Protection
Shutdown State
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:
STATe <on-off-state>
Select under current protection to
shutdown (ON) or set alarm
(OFF)
Yes
TM-XDOP-01XN.book Page 13 Monday, July 17, 2006 11:19 AM