XDC 6000 Watt and 12000 Watt Series DigitalProgrammable DC Power Supply Operating Manual
Remote Analog Operation
TM-XDOP-01XN 4–9
Press the LCL/RMT button to begin remote operation via the analog interface.
SCPI
To select which setpoints to control via analog programming lines, use the
command:
SYST:REM:SOUR {AVOL|ACUR|AVC}
Where
• AVOL (Analog VOLtage) selects only voltage to be programmed via the
analog programming lines
• ACUR (Analog CURrent) selects only current to be programmed via the
analog programming lines
• AVC (Analog Voltage and Current) selects voltage and current to be
programmed via the analog programming lines
To select the voltage level:
SYST:COMM:APR:LEV {5|10}
Where
“5” is the 0-5V range, and
“10” is the 0-10V range
To put the unit into remote control:
SYST:REM:STAT REM
Step # Do This You Will See
1ERROR MSGS
2
4 times
REMOTE SELECT
3
RS-232
4
or
Select desired option.
Analog V&I,
Analog V, or
Analog I
5
Setting is saved.
MENU
ENTER
ENTER
TM-XDOP-01XN.book Page 9 Monday, July 17, 2006 11:19 AM