DESCRIPTION
WCAP-FTXX Foil Capacitors
Order.- No.
890334023006CS
SIZE
A4
Size: Pitch 10.0 mm - PL 4
A Dimensions: [mm]
P ±0.5
L ±0.5
H ±0.5
W ±0.5
PL min.
Pin Ø ±0.05
d1
10.0
13.0
11.0
5.0
4.0
0.6
0.9
B Recommended hole pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Capacitance
Rated voltage
Isolation Resistance
Dissipation factor
Dissipation factor
Dissipation factor
Rate of Voltage Rise
Dielectric strength Pin to Pin
Dielectric strength Pin to Case
Test conditions
1 V/ 1 kHz ± 0.2 kHz
1 min @ 100V (DC)
@ 1 kHz
@ 10 kHz
@ 100 kHz
1 minute
1 minute
C
U
R
R
Iso
DF
DF
DF
dV/ dt
Value
0.0100
310
> 30000
< 0.10
< 0.10
< 0.50
500
1333
2000
Unit
µF
V (AC)
%
%
%
V/ µs
V (DC)
V (AC)
Tol.
± 10%
min.
max.
max.
max.
max.
E General information:
X2-Safety Class Capacitor
Storage Conditions: 35°C, <45% RH
Operating Temperature: -40°C to +105°C
Climate category: 40/ 105/ 56/ B
Maximum Selfheating (rated): 7°C
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
FIT according to separate documentation
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before