Datasheet

User’s Manual
Page 14 of 15
This document is only valid on the
date of printing: 2016-10-26
WERI Mini Applicator
I:\Specs\eiCan\WERI\ConTOOLC\Datasheet\User's Manual_WERI Mini Applicator.docx
10 Troubleshooting
Problem
Cause
Solution
The mini applicator is not
correctly mated to the press’
baseplate
The mating surfaces are not
clean and smooth
Clean the mating surfaces
The mini applicator is not
correctly centered under the
press
Verify the positioning of the
press “T” shank and
baseplate
While cycling manually the
press with the spanner,
something is blocking and
does not allow the cycle to
be completed
The press has not been set
to the correct shut height of
135.8 mm at bottom dead
center
Verify the press shut height
with a shut height gauge
The punches are too close to
the anvils
Set correctly the adjusting
rings of the continuous
adjusting head, as per the
mini applicator plate
The rubber spacer has not
been removed.
Remove the rubber spacer
The terminal does not fit in
the terminal feeding guide
The brake on the feeding
guide has not been released
Release the brake to allow
the guide to receive the
terminals
The terminal is not the good
one
Verify that the terminal part
number on the reel does
correspond to the terminal
part number on the mini
applicator plate.
The terminals are not
correctly moving towards the
anvil
Incorrect hooking of the
terminals by the feeding
finger
Manually cycle repeatedly
the press, making sure that
the feeding finger correctly
engages the terminals
The brake on the feeding
guide is not operating
Make sure the feeding guide
brake is on
The terminal is not correctly
aligned along the anvil axis
Incorrect hooking of the
terminals by the feeding
finger
Manually cycle repeatedly
the press, making sure that
the feeding finger correctly
engages the terminals
The feeding system
components are worn out
Adjust the feeding system
The reel unwinding is not
smooth
Make sure the reel can
unwind without obstacles
whatsoever and not
requiring an abnormal effort
to the feeding system