Design Guide Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information. Throughout this guide, dimensions may vary by ± 1/8" (3). Dimensions in parentheses are millimeters unless otherwise specified. 2 | Wolf Customer Care 800.222.
Contents Contents 4 M Series Ovens 16 E Series Ovens 30 L Series Oven 34 Convection Steam Ovens 40 Speed Ovens 46 Microwave Ovens 60 Warming Drawers 66 Induction/Electric Cooktops 74 Gas Cooktops 80 Module Cooktops 90 Coffee System 96 Cup Warming Drawer 100 Vacuum Seal Drawer 106 Dual Fuel Ranges 110 Gas Ranges 114 Induction Ranges 118 Sealed Burner Rangetops 122 Outdoor Grills/Modules 134 Cooktop Ventilation Hoods 146 Downdraft Ventilation 152 Pro Ventilation Hoods
M Series Ovens M Series Built-In Ovens Contemporary M series ovens include stainless steel and black glass models. Superior performance features include a more advanced dual vertical convection fan system, touchscreen controls, convenient preset cooking programs, and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M series ovens can be installed in a standard or flush inset application.
M Series Ovens 30" M Series Built-In Ovens TRANSITIONAL SINGLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 2 1/2" (65) 23" (584) BEHIND FRAME OPEN OVEN DOOR 21 3/8" (543) TRANSITIONAL DOUBLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 2 1/2" (65) 21 3/8" (543) 23" (584) BEHIND FRAME wolfapp
M Series Ovens 30" M Series Built-In Ovens PROFESSIONAL SINGLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 3 1/4" 23" (584) BEHIND FRAME (83) OPEN OVEN DOOR 21 3/8" (543) PROFESSIONAL DOUBLE OVEN 7/8" (22) UPPER OVEN 8 5/8" 1 7/8" (46) (218) LOWER OVEN 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 6 | 3 1/4" (83) Wolf Customer Ca
M Series Ovens 30" M Series Built-In Ovens CONTEMPORARY STAINLESS STEEL SINGLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 23" (584) BEHIND FRAME OPEN OVEN DOOR 21 3/8" (543) CONTEMPORARY STAINLESS STEEL DOUBLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 21 3/8" (543) 23" (584) BEHIND FRAME w
M Series Ovens 30" M Series Built-In Ovens CONTEMPORARY BLACK GLASS SINGLE OVEN 1" (25) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 23" (584) BEHIND FRAME OPEN OVEN DOOR 21 3/8" (543) CONTEMPORARY BLACK GLASS DOUBLE OVEN 1" (25) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 8 | Wolf Customer Care 800.222.
M Series Ovens Planning Information The M series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth. ELECTRICAL REQUIREMENTS Finish the edges of the opening. They may be visible when the door is open. Installation must comply with all applicable electrical codes.
M Series Ovens 30" M Series Single Oven STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 4" 27 1/2" (699) OPENING HEIGHT (102) 28 1/2" (724) OPENING WIDTH E E SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 10 | Wolf Customer Care 800.222.
M Series Ovens 30" M Series Single Oven FLUSH INSET INSTALLATION 7/8" (22) OR 1" (25)** 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW 30 1/8" (765) FLUSH INSET WIDTH*** 5" 11/8" (29) (127) E 4" (102) 28 3/4" (730) FLUSH INSET HEIGHT*** 13/16" (21) E 1/8" (3) SIDE VIEW E FRONT VIEW *1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
M Series Ovens 30" M Series Double Oven STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 4" (102) 49 7/8" (1267) OPENING HEIGHT 28 1/2" (724) OPENING WIDTH E E 17" (432) TYPICAL SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 12 | Wolf Customer Care 800.222.
M Series Ovens 30" M Series Double Oven FLUSH INSET INSTALLATION 7/8" (22) OR 1" (25)** 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW 30 1/8" (765) FLUSH INSET WIDTH*** 5" 11/8" (29) (127) E 4" (102) 51 1/8" (1299) FLUSH INSET HEIGHT*** 13/16" (21) E 1/8" (3) E 17" (432) TYPICAL SIDE VIEW FRONT VIEW *1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
M Series Ovens 30" M Series Single Oven DUAL STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 5" (127) 4" 27 1/2" (699) OPENING HEIGHT (102) FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation. 14 | Wolf Customer Care 800.222.
M Series Ovens 30" M Series Single Oven DUAL FLUSH INSET INSTALLATION 7/8" (22) 24" (610) FLUSH INSET DEPTH OR 1" (25)** FINISHED CLEATS* TOP VIEW 60 1/8" (1527) FLUSH INSET WIDTH*** 11/8" (29) 5" (127) E 5" (127) 4" 28 3/4" E 4" (102) (102) E E (730) FLUSH INSET HEIGHT*** 13/16" (21) 1/8" (3) SIDE VIEW FRONT VIEW *1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
E Series Ovens E Series Built-In Ovens Wolf E series ovens are crafted of stainless steel. The handles match the rest of the Wolf cooking appliance offering, providing a more cohesive look. E series ovens can be installed in a standard or flush inset application. E SERIES OVENS TRANSITIONAL SO24TE/S/TH SO3050TE/S/TH DO3050TE/S/TH PROFESSIONAL SO3050PE/S/PH DO3050PE/S/PH 16 | Wolf Customer Care 800.222.
E Series Ovens 24" E Series Built-In Oven TRANSITIONAL SINGLE OVEN 7/8" (22) 23 1/4" 23 1/2" (591) (597) 23 1/2" (597) 2 1/2" (64) 22" (559) 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR 18 1/8" (460) wolfappliance.
E Series Ovens 30" E Series Built-In Ovens TRANSITIONAL SINGLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 2 1/2" 23" (584) BEHIND FRAME (65) OPEN OVEN DOOR 21 3/8" (543) TRANSITIONAL DOUBLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 18 2 1/2" (65) | Wolf Customer Care 800.222.
E Series Ovens 30" E Series Built-In Ovens PROFESSIONAL SINGLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) 28 1/2" CONDUIT CHANNEL (723) 27" (686) 28 1/2" (724) 29 7/8" (759) 3 3/8" (86) 23" (584) BEHIND FRAME OPEN OVEN DOOR 21 3/8" (543) PROFESSIONAL DOUBLE OVEN 7/8" (22) 8 5/8" 1 7/8" (46) (218) 2" (51) 1 3/8" (36) CONDUIT CHANNEL 28 1/2" (724) 49 3/8" 50 7/8" (1254) (1291) OPEN OVEN DOOR 29 7/8" (759) 3 3/8" (86) 21 3/8" (543) 23" (584) BEHIND FRAME wolfapp
E Series Ovens Planning Information The E series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, the face trim overlaps stiles and rails. Refer to the chart below.
E Series Ovens Electrical Requirements 24" OVEN 30" OVEN Installation must comply with all applicable electrical codes. Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.
E Series Ovens 24" E Series Single Oven STANDARD INSTALLATION 23" (584) OPENING DEPTH TOP VIEW E 23 1/4" (591) OPENING HEIGHT 22 1/8" (562) OPENING WIDTH SIDE VIEW 22 | Wolf Customer Care 800.222.
E Series Ovens 24" E Series Single Oven FLUSH INSET INSTALLATION 24" (610) 7/8" (22) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 23 3/4" (603) FLUSH INSET HEIGHT** 3/8" (10) 13/16" (21) 1/8" (3) 23 3/4" (603) FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. wolfappliance.
E Series Ovens 30" E Series Single Oven STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 4" 27 1/2" (699) OPENING HEIGHT (102) 28 1/2" (724) OPENING WIDTH E E SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 24 | Wolf Customer Care 800.222.
E Series Ovens 30" E Series Single Oven FLUSH INSET INSTALLATION 7/8" (22) 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW 30 1/8" (765) FLUSH INSET WIDTH** 5" 11/8" (29) (127) E 4" (102) 28 3/4" (730) FLUSH INSET HEIGHT** 13/16" (21) E 1/8" (3) SIDE VIEW E FRONT VIEW *Shaded areas will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOTE: Location of electrical supply within opening may require additional cabinet depth. wolfappliance.
E Series Ovens 30" E Series Double Oven STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 4" (102) 49 7/8" (1267) OPENING HEIGHT 28 1/2" (724) OPENING WIDTH E E 17" (432) TYPICAL SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 26 | Wolf Customer Care 800.222.
E Series Ovens 30" E Series Double Oven FLUSH INSET INSTALLATION 7/8" (22) 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW 30 1/8" (765) FLUSH INSET WIDTH** 5" 11/8" (29) (127) E 4" (102) 51 1/8" (1299) FLUSH INSET HEIGHT** 13/16" (21) E 1/8" (3) E 17" (432) TYPICAL SIDE VIEW FRONT VIEW *Shaded areas will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOTE: Location of electrical supply within opening may require additional cabinet depth.
E Series Ovens 30" E Series Single Oven DUAL STANDARD INSTALLATION 23 1/4" (591) OPENING DEPTH TOP VIEW 5" (127) E 5" (127) 4" 27 1/2" (699) OPENING HEIGHT (102) FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation. 28 | Wolf Customer Care 800.222.
E Series Ovens 30" E Series Single Oven DUAL FLUSH INSET INSTALLATION 24" (610) FLUSH INSET DEPTH 7/8" (22) FINISHED CLEATS* TOP VIEW 60 1/8" (1527) FLUSH INSET WIDTH** 11/8" (29) 5" (127) E 5" (127) 4" 28 3/4" E 4" (102) (102) E E (730) FLUSH INSET HEIGHT** 13/16" (21) 1/8" (3) SIDE VIEW FRONT VIEW *1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry. ** Dimension provides minimum reveals.
L Series Oven L Series Built-In Oven Since their introduction, Wolf L series built-in ovens have taken the culinary world by storm— and not just for their stylish cobalt blue interior and 10 cooking modes. Thanks to a Wolf innovation called dual convection, the L series delivers faster, more consistent results for baking, roasting, broiling—even drying fruits. The Wolf L series oven is offered in the 36" width with unframed door style and tubular handle. 30 | Wolf Customer Care 800.222.
L Series Oven L Series Built-In Oven DIMENSIONS 9 5/8" (244) 3" (76) 8 7/8" (225) 24 3/8" (619) CONDUIT CHANNEL 23" (584) 34 1/8" (867) 35 5/8" (905) 3" (76) 24" (610) BEHIND FRAME OPEN OVEN DOOR 17 3/4" (451) wolfappliance.
L Series Oven Planning Information If a cooktop is being installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
L Series Oven 36" L Series Single Oven STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 5" (127) 4" 24 1/16" (611) OPENING HEIGHT E (102) 34 1/2" (876) OPENING WIDTH E E SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. wolfappliance.
Convection Steam Ovens Convection Steam Ovens The legacy of the “combination oven” goes back decades, to innovative chefs in America and Europe who embraced the combination of air movement with superheated steam to achieve superior results—from breads and roasts to delicate fishes, seafood, and vegetables. Wolf combines the benefits of convection and steam for the most innovative steam oven on the market today.
Convection Steam Ovens Convection Steam Ovens TRANSITIONAL 7/8" (22) 21 3/16" (538) 17 1/2" 17 7/8" (446) (454) W WIDTH 2 1/2" (64) 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR WIDTH 14 3/16" (360) W 24" Transitional 231/2" (597) 30" Transitional 297/8" (759) wolfappliance.
Convection Steam Ovens Convection Steam Ovens PROFESSIONAL 7/8" (22) (446) (454) (759) 3 1/4" (83) (538) 17 1/2" 17 7/8" 29 7/8" 21 3/16" 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR 14 3/16" (360) CONTEMPORARY 7/8" (22) (446) (454) (759) 2 1/2" (64) (538) 17 1/2" 17 7/8" 29 7/8" 21 3/16" 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR 36 | Wolf Customer Care 800.222.
Convection Steam Ovens Planning Information The convection steam oven can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the door is open. For standard installations, the face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
Convection Steam Ovens Convection Steam Oven STANDARD INSTALLATION 23" (584) OPENING DEPTH TOP VIEW E 17 11/16" (449) OPENING HEIGHT W OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions. OPENING WIDTH W 24" Model 221/8" (562) 30" Model 221/8" (562) 38 | Wolf Customer Care 800.222.
Convection Steam Ovens Convection Steam Oven FLUSH INSET INSTALLATION 7/8" (22) 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 5/16" (8) 18 1/8" (460) FLUSH INSET HEIGHT** A 1/8" (3) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 24" Model 233/4" (603) 13/16" (21) 30" Model 301/8" (765) 4" (102) wolfappliance.
Speed Ovens Speed Ovens The Wolf speed oven has features that make fast meals better meals. Available in 24" and 30" widths, they are designed to match Wolf transitional, professional, and contemporary products. The speed oven can be installed in a standard or flush inset application. SPEED OVENS TRANSITIONAL SPO24TE/S/TH SPO30TM/S/TH PROFESSIONAL SPO30PM/S/PH CONTEMPORARY SPO30CM/B/TH 40 | Wolf Customer Care 800.222.
Speed Ovens Speed Ovens TRANSITIONAL 7/8" (22) 21 3/16" (538) 17 1/2" 17 7/8" (446) (454) W WIDTH 2 1/2" (64) 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR WIDTH 14 3/16" (360) W 24" Transitional 231/2" (597) 30" Transitional 297/8" (759) wolfappliance.
Speed Ovens Speed Ovens PROFESSIONAL 7/8" (22) (446) (454) (759) 3 1/4" (83) (538) 17 1/2" 17 7/8" 29 7/8" 21 3/16" 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR 14 3/16" (360) CONTEMPORARY 7/8" (22) (446) (454) (759) 2 1/2" (64) (538) 17 1/2" 17 7/8" 29 7/8" 21 3/16" 21 1/2" (546) BEHIND FRAME OPEN OVEN DOOR 42 | Wolf Customer Care 800.222.
Speed Ovens Planning Information The speed oven can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the door is open. For standard installations, the face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
Speed Ovens Speed Oven STANDARD INSTALLATION 23" (584) OPENING DEPTH TOP VIEW E 17 11/16" (449) OPENING HEIGHT W OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions. OPENING WIDTH W 24" Model 221/8" (562) 30" Model 221/8" (562) 44 | Wolf Customer Care 800.222.
Speed Ovens Speed Oven FLUSH INSET INSTALLATION 7/8" (22) 24" (610) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 5/16" (8) 18 1/8" (460) FLUSH INSET HEIGHT** A 1/8" (3) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 24" Model 233/4" (603) 13/16" (21) 30" Model 301/8" (765) 4" (102) wolfappliance.
Microwave Ovens Microwave Ovens As true cooking instruments, Wolf microwave ovens have features that make fast meals better meals. The drop-down door microwaves feature a door that hinges at the bottom for easier access to foods. Available in 24" and 30" widths, they are designed to match Wolf transitional, professional, and contemporary products. Drawer microwave ovens can be conveniently located undercounter, in a corner, or below an oven.
Microwave Ovens Drop-Down Door Microwave Ovens TRANSITIONAL 7/8" (22) 21 3/16" (538) 17 1/2" 17 7/8" (446) (454) W WIDTH 2 1/2" (64) 20" (508) BEHIND FRAME OPEN OVEN DOOR WIDTH 14 3/16" (360) W 24" Transitional 231/2" (597) 30" Transitional 297/8" (759) PROFESSIONAL 7/8" (22) (446) (454) (759) 3 1/4" (83) (538) 17 1/2" 17 7/8" 29 7/8" 21 3/16" 20" (508) BEHIND FRAME OPEN OVEN DOOR 14 3/16" (360) CONTEMPORARY 7/8" (22) (446) (454) (759) 2 1/2" (64) (538) 17 1/2" 17 7/8" 2
Microwave Ovens Drawer Microwave Ovens TRANSITIONAL / PROFESSIONAL 21 5/8" (549) 11/4" (32) 13/4" POWER CORD (45) 15 1/8" 4 5/8" (118) 14 5/8" (384) 29 7/8" (759) CHANNEL (372) 21 7/8" (556) BEHIND FRAME OPEN DRAWER 16 1/2" (419) WIDTH W 24" Model 237/8" (606) 30" Model 297/8" (759) 48 | Wolf Customer Care 800.222.
Microwave Ovens Convection Microwave Oven Standard Microwave Oven M/E SERIES TRIM M/E SERIES TRIM /8" OR 1"1 3(25) 11(35) /4" (32)* 3/4(610) 24" 24 " (629) FREESTANDING FREESTANDING 13 1437//88"" 1871//84"" 19 14 7/8" (340) (378) FREEFREESTANDING STANDING (464) (505) WITH WITH TRIM TRIM (378) FREESTANDING 24" (610) FREESTANDING 5 " (448) 17 18"/8(457) BEHINDTRIM TRIM BEHIND TRIM TRIM WIDTH WIDTH 1" (25) OR 11/4" (32)* 18 1/4" 13 3/8" (464) WITH TRIM (340) FREESTANDING 18" (457) BEHIND TR
Microwave Ovens Planning Information DROP-DOWN DOOR MICROWAVE DRAWER MICROWAVE The drop-down door microwave oven can be installed in a standard or flush inset application. The drawer microwave oven can be installed in a standard or flush inset application. The location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, the face trim will overlap stiles and rails.
Microwave Ovens Planning Information Electrical Requirements CONVECTION / STANDARD MICROWAVES Installation must comply with all applicable electrical codes. Convection and standard microwave ovens can be installed in a standard or flush inset application using accessory trim to match Wolf ovens. Trim kits are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Microwave Ovens Drop-Down Door Microwave Oven STANDARD INSTALLATION 21 9/16" (548) OPENING DEPTH TOP VIEW E 17 11/16" (449) OPENING HEIGHT W OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions. OPENING WIDTH W 24" Model 221/8" (562) 30" Model 221/8" (562) 52 | Wolf Customer Care 800.222.
Microwave Ovens Drop-Down Door Microwave Oven FLUSH INSET INSTALLATION 7/8" (22) 23" (584) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 5/16" (8) 18 1/8" (460) FLUSH INSET HEIGHT** A 1/8" (3) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 24" Model 233/4" (603) 13/16" (21) 30" Model 301/8" (765) 4" (102) wolfappliance.
Microwave Ovens Drawer Microwave Oven STANDARD INSTALLATION 22" (559) OPENING DEPTH TOP VIEW ANTI-TIP BLOCK E 14 3/4" (375) OPENING HEIGHT W OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: All drawer microwave ovens require the same opening dimensions. OPENING WIDTH W 1/8" (562) 24" Model 22 30" Model 22 1/8" (562) 54 | Wolf Customer Care 800.222.
Microwave Ovens Drawer Microwave Oven FLUSH INSET INSTALLATION 11/4" (32) 23 1/4" (591) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW ANTI-TIP BLOCK E 15 15/16" (405) 7/16" (11) A FLUSH INSET HEIGHT** 3/4" (19) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 24" Model 24 1/8" (613) 1" (25) 30" Model 30 1/8" (765) 4" (102) wolfappliance.
Microwave Ovens Convection Microwave Oven STANDARD INSTALLATION WITH TRIM 20 1/8" (511) OPENING DEPTH TOP VIEW E 18 7/8" (479) OPENING HEIGHT W OPENING WIDTH SIDE VIEW OPENING WIDTH FRONT VIEW W 27" Trim 251/4" (641) 30" Trim 271/2" (699) 36" Trim 333/8" (854) 56 | Wolf Customer Care 800.222.
Microwave Ovens Convection Microwave Oven FLUSH INSET INSTALLATION WITH TRIM 1" (25) 23 1/4" (591) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 20 1/8" (511) 3 / 8" (10) A FLUSH INSET HEIGHT** 7/ 8" (22) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 27" Trim 271/8" (689) 15/16" (24) 30" Trim 301/8" (765) 13/16" (30) wolfappliance.
Microwave Ovens Standard Microwave Oven STANDARD INSTALLATION WITH TRIM 20" (508) OPENING DEPTH TOP VIEW E 17" (432) OPENING HEIGHT W OPENING WIDTH SIDE VIEW OPENING WIDTH FRONT VIEW W 27" Trim 251/4" (641) 30" Trim 271/2" (699) 58 | Wolf Customer Care 800.222.
Microwave Ovens Standard Microwave Oven FLUSH INSET INSTALLATION WITH TRIM 1" (25) 23 1/4" (591) FLUSH INSET DEPTH FINISHED CLEATS* TOP VIEW E 18 1/2" (470) 11/16" (17) A FLUSH INSET HEIGHT** 13 /16" (21) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 27" Trim 271/8" (689) 15/16" (24) 30" Trim 301/8" (765) 13/16" (30) wolfappliance.
Warming Drawers Warming Drawers Wolf warming drawers are designed to take care of prepared foods until it’s time to serve them. You can adjust the temperature, keeping moist foods moist, and crisp foods crisp. Warming drawers are ideal for proofing dough. They can also be used to warm robes and towels. Drawer fronts are available to match the look of Wolf ovens, sealed burner rangetops, and outdoor grills. The integrated drawer front allows for a custom panel and handle.
Warming Drawers Warming Drawers DRAWER FRONT OPTIONS DIMENSIONS A Wolf warming drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a custom panel. The panel mounting kit is available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Warming Drawers Planning Information The warming drawer must be installed with a Wolf drawer front, available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Specific installation instructions are included with the drawer front. The warming drawer can be installed in a standard or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame.
Warming Drawers Planning Information ELECTRICAL REQUIREMENTS Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the warming drawer can be placed in an adjacent cabinet within reach of the power cord.
Warming Drawers Warming Drawer STANDARD INSTALLATION 23" (584) OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT E 28 5/8" (727) OPENING WIDTH SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 64 | Wolf Customer Care 800.222.
Warming Drawers Warming Drawer FLUSH INSET INSTALLATION A DRAWER FRONT DEPTH 24" (610) FLUSH INSET DEPTH*** FINISHED CLEATS* TOP VIEW ANTI-TIP BLOCK 10 5/8" 3/4" (19) (270) FLUSH INSET HEIGHT** 3/4" (19) E 3/4" (19) E 30 1/8" (765) FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. ***24 1/8" (613) for E series contemporary drawer front.
Induction/Electric Cooktops Induction/Electric Cooktops 66 | Wolf Customer Care 800.222.
Induction Cooktops Induction Cooktops Almost instantaneous temperature response. Practically no wasted heat. Induction cooking has been popular among European chefs and homeowners for decades. Now Wolf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. Electromagnetic elements cause iron and magnetic stainless cookware to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan.
Induction Cooktops Induction Cooktops 24" TRANSITIONAL 30" TRANSITIONAL 21" 21" CONDUIT 30" (762) 2" (51) 24" CONTEMPORARY 2" (51) CONDUIT 2" (51) 7/8" 11/4" (32) (22) 30" CONTEMPORARY 36" CONTEMPORARY 21" 21" 21" (533) (533) 36" (914) 30" (762) 2 1/2" (64) 7/8" 11/4" (32) (22) 68 CONDUIT (533) 23 5/8" (600) CONDUIT (533) 36" (914) 7/8" 11/4" (32) (22) 7/8" 11/4" (32) (22) 21" (533) (533) 23 5/8" (600) 36" TRANSITIONAL | Wolf Customer Care 800.222.
Electric Cooktops Electric Cooktops Wolf electric cooktops use high-frequency pulsation technology for the most exceptional performance and control ever in a Wolf electric cooktop, with blazing hot sears at the high end and steady simmers and melts at the low end—a low-end finesse that is unusual in an electric cooktop. The updated element configuration accommodates a wide variety of cooking vessels and dish preparation.
Electric Cooktops Electric Cooktops 30" TRANSITIONAL 36" TRANSITIONAL 21" 21" (533) (533) 30" (762) 36" (914) CONDUIT 3 1/2" (89) 7/8" 11/4" (32) (22) CONDUIT 7/8" 11/4" (32) (22) 30" CONTEMPORARY 36" CONTEMPORARY 21" 21" (533) (533) 36" (914) 30" (762) CONDUIT 4" (102) 7/8" 11/4" (32) (22) 70 | 3 1/2" (89) Wolf Customer Care 800.222.
Induction/Electric Cooktops Planning Information A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. Contemporary induction and electric cooktops can be mounted flush with the top of the countertop, or as a frameless standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cutout must be provided.
Induction/Electric Cooktops 24" / 30" / 36" Cooktop STANDARD INSTALLATION 2 1/2" (64) W 19 1/2" WIDTH (495) 2 1/2" (64) COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 2" (51) 4 1/2" (114) 3 1/2" (89) E 10" (254) 36" (914) min FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical supply location only applies to installations with built-in oven.
Induction/Electric Cooktops 24" / 30" / 36" Cooktop FLUSH INSTALLATION 2 1/2" (64) COUNTERTOP PROFILE 5/16" (8) W 211/8" CUTOUT WIDTH (537) RECESS A 19 1/2" (495) RECESS 2 1/2" (64) 19/16" (40) min COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 2" (51) 4 1/2" (114) 3 1/2" (89) E 10" (254) 36" (914) min FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this ar
Gas Cooktops Gas Cooktops Like their oven counterparts, Wolf gas cooktops feature three unique looks—transitional, professional, and contemporary. Performance enhancements make delicious results even more of a certainty than ever. Multiple sizes, choice of knob colors, and distinctly different grates. For a striking, low-profile look, the contemporary gas cooktop fits flush to the countertop with frontmounted controls that integrate directly into cabinetry below.
Gas Cooktops Gas Cooktops 24" TRANSITIONAL 30" TRANSITIONAL 36" TRANSITIONAL 21" 21" 21" (533) (533) (533) 23 5/8" (600) 36" (914) 30" (762) 4" (102) 4" (102) 4" (102) 3/8" 7/8" 7/8" (10) (22) (22) 30" PROFESSIONAL 36" PROFESSIONAL 21" 21" (533) (533) 36" (914) 30" (762) 4" (102) 4" (102) 7/8" 7/8" (22) (22) 36" CONTEMPORARY 20 15/16" (532) 35 15/16" (913) 6 3/4" (171) 7/8" (22) wolfappliance.
Gas Cooktops Planning Information A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. If the cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units. The contemporary gas cooktop can be mounted flush with the top of the countertop, or as a standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cutout must be provided.
Gas Cooktops 24" / 30" / 36" Transitional / Professional Gas Cooktop STANDARD INSTALLATION 2 1/2" (64) W 19 1/2" WIDTH (495) 2 1/2" (64) COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 9" (229) 4" (102) 3 1/2" (89) E G 10" (254) SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical and gas supply location only applies to installations with built-in oven.
Gas Cooktops 36" Contemporary Gas Cooktop STANDARD INSTALLATION 2 1/2" (64) 35" (889) CUTOUT WIDTH 20" (508) COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 9" (229) 2" (51) MIN – 5" (127) MAX 4" 3 7(102) /8" (98) MIN –51/8" (130) MAX 5" (127) 10" 11/4" (32) DIAMETER (254) CL SIDE VIEW E G FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Maximum facade thickness 1" (25).
Gas Cooktops 36" Contemporary Gas Cooktop FLUSH INSTALLATION 2 1/2" (64) COUNTERTOP PROFILE 5/64" (2) 35" (889) CUTOUT WIDTH 21" (533) MIN RECESS 20" (508) 36" (914) MIN RECESS COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 9" (229) 2" (51) MIN – 5" (127) MAX 4" 3 7(102) /8" (98) MIN –51/8" (130) MAX 5" (127) 10" 11/4" (32) DIAMETER (254) CL SIDE VIEW CL E G FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials can
Module Cooktops Module Cooktops Wolf modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates, and trim allow them to integrate perfectly with their larger counterparts and deliver equal performance. Combine modules à la carte-style to create a custom cooktop, or add specialty functions alongside an existing cooktop.
Module Cooktops Module Cooktops INDUCTION ELECTRIC STEAMER FRYER 21" 21" 21" 21" (533) (533) (533) (533) 15" 15" 15" 15" (381) (381) (381) (381) CONDUIT 2" (51) CONDUIT 3 1/2" (89) 8 3/4" 11/4" (22) 11/4" (32) (32) 7/8" (22) 7/8" (22) GRILL TEPPANYAKI 4" 4" (102) (22) (102) 21" 21" (533) 15" 15" (381) (381) 5" MULTIFUNCTION 7/8" (22) 21" 21" (533) (533) 15" 15" (381) (381) 4" (102) 4" (102) (127) DRAIN OUTLET GAS (533) (222) 7/8" DRAIN OUTLET 7
Module Cooktops Planning Information IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the steamer, fryer, or grill modules. A minimum 2" (51) is required from the bottom of the module to combustible materials. For the teppanyaki module, a minimum 7/8" (22) is required from the bottom of the unit to any material. Refer to the illustrations on the following pages for installation of modules.
Module Cooktops Planning Information ELECTRICAL DRAIN OUTLET Installation must comply with all applicable electrical codes. Steamer and fryer modules require a method for draining hot water and oil. For the steamer module, options include connecting a drain hose from the 5/8" (16) outlet tied into an existing drain, a separate drain with freefall, or placing a heat-resistant receptacle under the drain outlet.
Module Cooktops Planning Information GAS SUPPLY GAS REQUIREMENTS Installation must comply with all applicable gas codes. Gas Supply If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended. Gas Inlet When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.
Module Cooktops Induction / Electric Module STANDARD INSTALLATION 2 1/2" (64) 14" 19 1/2" (356) (495) 2 1/2" (64) COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 2" (51) E 36" (914) min FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. wolfappliance.
Module Cooktops Steamer Module STANDARD INSTALLATION 2 1/2" (64) min 14" 19 1/2" (356) (495) 2 1/2" (64) min COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 7" (178) 7 7/8" (200) 6" 12 3/8" (152) (314) DRAIN OUTLET E SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. WARNING The steamer module must be installed at least 15" (381) from a fryer module.
Module Cooktops Fryer Module STANDARD INSTALLATION 2 1/2" (64) min 14" 19 1/2" (356) (495) 2 1/2" (64) min COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 7" (178) 7 7/8" (200) 6" 12 3/8" (152) (314) DRAIN OUTLET E SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
Module Cooktops Grill / Teppanyaki Module STANDARD INSTALLATION 2 1/2" (64) min 14" 19 1/2" (356) (495) 2 1/2" (64) min COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 7" (178) E SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 88 | Wolf Customer Care 800.222.
Module Cooktops Gas / Multifunction Module STANDARD INSTALLATION 2 1/2" (64) 14" 19 1/2" (356) (495) 2 1/2" (64) COUNTERTOP CUTOUT 13" 18" 30" (330) (457) (762) 7" (178) E SIDE VIEW G FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. wolfappliance.
Coffee System Coffee System Make professional-quality coffee, espresso, cappuccino, latte, and more. The Wolf coffee system automatically steams and foams the milk perfectly. The water temperature and brew strength are adjustable. It uses either whole-bean or ground coffee. The design pairs beautifully, either side-by-side or in a tower application, with other Wolf products such as the convection steam oven. The coffee system can be installed in a standard or flush inset application.
Coffee System Coffee System DIMENSIONS 7/8" (22) 17 7/8" (454) W WIDTH WIDTH 18" (457) BEHIND FRAME UNIT FULL EXTENSION 181/4" (464) W 24" Model 231/2" (597) 30" Trim 297/8" (759) wolfappliance.
Coffee System Planning Information The coffee system can be installed in a standard or flush inset application. Trim kits are available for vertical, single and horizontal configurations. All 30" trim options are based on model EC24/B. There are no trim options for model EC24/S. The sides of the cabinetry opening must be adequate to support installation of the mounting slides. Refer to the illustration below. Finish the edges of the opening. They may be visible when the unit is slid forward.
Coffee System Planning Information ELECTRICAL REQUIREMENTS Installation must comply with all applicable electrical codes. Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Coffee System Coffee System STANDARD INSTALLATION 21 9/16" (548) OPENING DEPTH SLIDE SUPPORT TOP VIEW 17 11/16" (449) SLIDE SUPPORT E OPENING HEIGHT W OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 24" (610) model and model with 30" (762) trim require the same opening dimensions. OPENING WIDTH W 24" Model 221/8" (562) 30" Trim 221/8" (562) 94 | Wolf Customer Care 800.222.
Coffee System Coffee System FLUSH INSET INSTALLATION 23" (584) SLIDE SUPPORT FLUSH INSET DEPTH 7/8" (22) FINISHED CLEATS* TOP VIEW 5/16" (8) SLIDE SUPPORT 18 1/8" (460) FLUSH INSET HEIGHT** A E 1/8" (3) W FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. FLUSH INSET WIDTH W A 24" Model 233/4" (603) 13/16" (21) 30" Trim 301/8" (765) 4" (102) wolfappliance.
Cup Warming Drawer Cup Warming Drawer The Wolf cup warming drawer preheats cups so hot beverages stay hot longer. The temperature is adjustable. Two model options match the look of Wolf stainless and black coffee systems. The cup warming drawer can be installed in a standard or flush inset application. 96 | Wolf Customer Care 800.222.
Cup Warming Drawer Cup Warming Drawer Planning Information DIMENSIONS The cup warming drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open. 5 1/2" (140) 23 1/2" (597) 7/8" (22) 21" (533) BEHIND FRAME For standard installations, the face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 1/8" (3) reveal is required on all sides.
Cup Warming Drawer Cup Warming Drawer STANDARD INSTALLATION 22 1/2" (572) OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 5 1/2" (140) OPENING HEIGHT E 22 1/8" (562) OPENING WIDTH SIDE VIEW 98 | Wolf Customer Care 800.222.
Cup Warming Drawer Cup Warming Drawer FLUSH INSET INSTALLATION 23 1/2" (597) FLUSH INSET DEPTH 7/8" (22) FINISHED CLEATS* TOP VIEW 1/8" (3) ANTI-TIP BLOCK 5 3/4" (146) FLUSH INSET HEIGHT** 13/16" (21) E 1/8" (3) 23 3/4" (603) FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. wolfappliance.
Vacuum Seal Drawer Vacuum Seal Drawer The vacuum seal drawer can be installed in a standard or flush inset application. Stainless steel, black glass, and integrated drawer fronts are available in 24" and 30" widths. The integrated drawer front allows for a custom panel. 100 | Wolf Customer Care 800.222.
Vacuum Seal Drawer Dimensions VACUUM SEAL DRAWER DRAWER FRONT 5 1/2" 5 1/2" (140) (140) 23 1/2" (597) 7/8" (22) 21" (533) BEHIND FRAME W DRAWER FRONT W 24" Drawer Front 231/2" (597) 30" Drawer Front 297/8" (759) INTEGRATED DRAWER FRONT DRAWER FULL EXTENSION 17" (432) A panel mounting kit is required when installing a custom panel. IMPORTANT NOTE: A handle cannot be installed on the custom panel. The panel mounting kit is available through an authorized Wolf dealer.
Vacuum Seal Drawer Planning Information The vacuum seal drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. FILLER A filler is required if installed below a countertop. The lid is designed to remain open at 60°. Refer to the illustration below.
Vacuum Seal Drawer Planning Information ELECTRICAL REQUIREMENTS Installation must comply with all applicable electrical codes. Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Vacuum Seal Drawer Vacuum Seal Drawer STANDARD INSTALLATION 22 1/2" (572) OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 5 9/16" (141) OPENING HEIGHT E 22 1/8" (562) OPENING WIDTH SIDE VIEW 104 | FRONT VIEW Wolf Customer Care 800.222.
Vacuum Seal Drawer Vacuum Seal Drawer FLUSH INSET INSTALLATION 23 1/2" (597) FLUSH INSET DEPTH 7/8" (22)** FINISHED CLEATS* TOP VIEW 1/16" (2) ANTI-TIP BLOCK 5 3/4" (146) FLUSH INSET HEIGHT*** A E 1/8" (3) W FLUSH INSET WIDTH*** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Cleat depth assumes a stainless steel, black glass, or 3/4" (19) custom panel. ***Dimension provides minimum reveals.
Dual Fuel Ranges Dual Fuel Ranges Discover a new world of cooking—the best of two worlds, actually—with a Wolf dual fuel range. Topside, gas cooking in all its glory, with the fine control of dual-stacked, sealed burners and options that include the remarkable French top. Below, that marvel of culinary technology, the Wolf convection electric oven. Its two fans and four heating elements let you select from 10 cooking modes so you can choose the one precisely suited to the dish you’re preparing.
Dual Fuel Ranges Dual Fuel Ranges 29 1/2" (749) 29 1/2" (749) 26 7/8" (683) 26 7/8" (683) 30" RANGE 36" RANGE 36 1/2" 35 1/2" (927) (902)* 24" (610) 36 1/2" 35 1/2" 36 1/2" (927) 35 1/2" (902)* (927) (902)* 26" (660) 47 7/8" (1216) 47 1/4" (1200) 26" (660) 35 7/8" (911) 29 7/8" (759) 48" RANGE 24" (610) 47 1/4" (1200) *35 1/2" (902) MIN TO 38" (965) MAX *35 1/2" (902) MIN TO 38" (965) MAX * 1/12/"2"(749) (749) 29 29 7/78/"8(683) 26 26 " (683) 60" RANGE 24" 24"(610) (610) 7/7
Dual Fuel Ranges Planning Information IMPORTANT NOTE: When installing against a combustible surface, a minimum 10" (254) riser is required for a 36" dual fuel range with charbroiler or griddle and all 48" and 60" models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. GAS SUPPLY A Wolf pro ventilation hood is recommended with the dual fuel range. Refer to page 152 for Pro Ventilation.
Dual Fuel Ranges Dual Fuel Range INSTALLATION 13" 18" 30" (762) TO 36" (914) (330) (457) TO BOTTOM OF VENTILATION HOOD* 6" (152) W OPENING WIDTH ELECTRICAL AND GAS IN ‘A’ LOCATION ONLY 2" (51) 8 1/2" A 4 7/8" (124) SIDE VIEW E (216) G FRONT VIEW *Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler. NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Gas Ranges Gas Ranges Wolf gas ranges offer the same function, durability and exhilarating performance our ranges have become famous for. Now add the fine control of dual-stacked, sealed burners for gas cooking with superior results. Choose from a multitude of sizes and features to fit your cooking style. Standard features include an infrared broiler and convection baking. Options include infrared griddle, charbroiler, and the innovative French top.
Gas Ranges 28 3/8" (721) 28 3/8" (721) 27" (686) 27" (686) 56" (1422) 9 1/4" Gas Ranges 9 1/4" (235) 30" RANGE 37" 36" (914) 41" 48" (1041) RANGE 25 3/8" (645) 37" (940)* 2 1/2" 37" 46" (1168) 41" (1041) 25 3/8" (645) 36" (940)* (914) 37" 37" 36" (940)*(940)* (914) 2 1/2" (64) 29 7/8" (759) (235) 46" (1168) 36" RANGE (940)* 56" (1422) 2 1/2" (64) (64) 35 7/8" (911) 43 3/8" (1102) 47 7/8" (1216) 43 3/8" (1102) *37" (940) MIN TO 38" (965) MAX.
Gas Ranges Planning Information When installing against a combustible surface, a minimum 20" (508) riser is required. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. A Wolf pro ventilation hood is recommended with the gas range. Refer to page 152 for Pro Ventilation. ELECTRICAL REQUIREMENTS Installation must comply with all applicable electrical codes.
Gas Ranges Gas Range INSTALLATION 13" 18" 30" (762) TO 36" (914) (330) (457) TO BOTTOM OF VENTILATION HOOD* 6" (152) W OPENING WIDTH 12" 10" (254) (305) 5 3/4" (146) LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR 3" (76) SIDE VIEW 7 3/4" (197) FRONT VIEW E 2" (51) G 12" 5" (305) GAS (127) *Without ventilation hood, 42" (1067) minimum clearance countertop to combustible materials, charbroiler and GR488 require non-combustible materials.
Induction Ranges Induction Ranges Experience a new way of cooking with a Wolf induction range. Magnetism allows the ultrafast, energy efficient surface elements to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan. The cooktop’s surface remains cool. Your kitchen stays cooler too. The electric convection oven with two fans and four heating elements let you select from ten cooking modes and is self-cleaning.
Induction Ranges Induction Ranges 30" RANGE 36" RANGE 28 1/4" (718) 28 1/4" (718) 27 1/2" (699) 27 1/2" (699) 24 1/4" (616) 24 1/4" (616) 35 1/2" 35 1/2" (902)* (902)* 29 7/8" (759) 26 3517/48" (667) (911) 26 1/4" (667) 47 1/4" (1200) 47 1/4" (1200) *35 1/2" (902) MIN TO 38" (965) MAX *35 1/2" (902) MIN TO 38" (965) MAX SIDE VIEW—ALL RANGES wolfappliance.
Induction Ranges Planning Information Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. ELECTRICAL REQUIREMENTS Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.
Induction Ranges Induction Range INSTALLATION 13" 18" 30" (762) TO 36" (914) (330) (457) TO BOTTOM OF VENTILATION HOOD* 6" (152) W OPENING WIDTH A ELECTRICAL IN ‘A’ LOCATION ONLY 2" (51) 4 7/8" (216) E (124) SIDE VIEW 8 1/2" FRONT VIEW *Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials. NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces. Combustible materials cannot be located within this area.
Sealed Burner Rangetops Sealed Burner Rangetops Wolf sealed burner rangetops incorporate all the gas cooking features of a Wolf dual fuel range. Customize your rangetop with your preferred combination of burners, infrared griddle, charbroiler, French top, or wok burner. All sealed burner rangetop models are constructed of stainless steel and can be ordered in natural or LP gas.
Sealed Burner Rangetops 28 1/2" (724) 27 1/2" (699) 9 1/4" Sealed Burner Rangetops (235) 17 1/2" (445) 12 1/2" (318) 30" RANGETOP 8 1/2" (216) 7 1/2" (191) 8 1/2" (216) 24 1/8" (613) 29 7/8" (759) 26 1/8" (664) 28 1/2" (724) 27 1/2" (699) 9 1/4" 36" RANGETOP (WOK MODEL SHOWN) (235) 11/2" (38) 8 1/2" (216) 17 1/2" (445) 12 1/2" (318) 7 1/2" (191) 8 1/2" (216) 24 1/8" (613) 35 7/8" (911) 26 1/8" (664) 28 1/2" (724) 27 1/2" (699) 9 1/4" (235) 48" RANGETOP 12 1/2" (318) 8 1/2" (216) 47 7/
Sealed Burner Rangetops Planning Information The platform to support the sealed burner rangetop must include a cutout for electrical and gas supply connections. Refer to the chart below for minimum base support. When installing against a combustible surface, a minimum 5" (127) riser is required for model SRT366, and a minimum 10" (254) riser is required for 36" and 48" sealed burner rangetops with a charbroiler or griddle.
Sealed Burner Rangetops Sealed Burner Rangetop INSTALLATION 13" 18" 30" (762) TO 36" (914) (330) (457) TO BOTTOM OF VENTILATION HOOD* 6" (152) 7 1/2" (191) W OPENING HEIGHT 24" (610) MAX OPENING WIDTH PLATFORM PLATFORM 4" PLATFORM TOP VIEW (102) BACK WALL E G 16" (406) ELECTRICAL AND GAS SIDE VIEW FRONT VIEW *Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
Outdoor Grills/Modules Outdoor Grills/Modules Taste what happens when the heritage of professional cooking moves from the kitchen to the patio. Like their indoor counterparts, Wolf outdoor grills are precision instruments. Constructed of heavy-duty stainless steel, the 30", 36", 42", and 54" grills have powerful burners every five inches for even heat distribution. An electric rotisserie with infrared burner produces succulent poultry and roasts.
Outdoor Grills/Modules Outdoor Grills and Modules OUTDOOR GRILL 30" (762) HOOD CLOSED 27" (686) 2 1/2" 12 1/2" (318) TO GRILLING SURFACE (64) CLEARANCE FOR OPEN HOOD 27 3/4" (705) W WIDTH GRILL CART 12" (305) 24" (610) 36 1/2" (927) TO GRILL PLATFORM 3" (76) 27 3/4" (705) W WIDTH MAX DOOR/DRAWER CLEARANCE 22" (559) BURNER MODULE / SIDE BURNER 30" (762) 10 3/4" (273) 13" (330) OUTDOOR GRILL W OG30 30" (762) OG36 36" (914) OG42 42" (1067) OG54 54" (1372) 27 3/4" (705) GRILL CART
Outdoor Grills/Modules Planning Information For portable applications, Wolf grill carts are designed specifically to fit grill models OG30, OG36, and OG42 and the side burner. Model OG54 is designed for built-in applications only. For built-in applications, Wolf outdoor grills and the burner module are designed for easy placement into a built-in enclosure. For outdoor grills, installation in a combustible enclosure requires an insulating liner. For the burner module, an insulating liner is not required.
Outdoor Grills/Modules GAS SUPPLY GAS REQUIREMENTS Installation must comply with all applicable gas codes. Gas Supply If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended. Gas Inlet If the outdoor grill is being connected to a whole house LP supply, the LP gas pressure regulator is not provided. It can be purchased from an authorized Wolf dealer.
Outdoor Grills/Modules Outdoor Grill NON-COMBUSTIBLE INSTALLATION COMBUSTIBLE INSTALLATION 12" (305) 2 1/2" (64) 13" 24 1/4" (616) G (330) OPENING DEPTH 10 3/4" OPENING DEPTH 31/2" (89) 6" (273) C L 26" (660) GRILL OVERLAP 2 3/4" (70) KNOCKOUT 12" (152) LINER OVERLAP G CL 5" (127) (305) TOP VIEW TOP VIEW W W OPENING WIDTH OPENING WIDTH 11 3/4" 12 5/8" 6" (298) OPENING HEIGHT (321) OPENING HEIGHT (152) 4" (102) G 13/16" (21) 13/16" (21) LINER OPENING GRILL OPENING COUNTER
Outdoor Grills/Modules Burner Module INSTALLATION 12" (305) G 3" (76) 24 1/4" (616) MODULE OVERLAP OPENING DEPTH 6" (152) TOP VIEW 12" (305) OPENING 10" (254) OPENING HEIGHT G 8" (203) 7" (178) 9/16" (14) MODULE OPENING COUNTERTOP OVERHANG FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. An insulating liner is not required. wolfappliance.
Outdoor Accessories Outdoor Accessories ACCESS DOORS ACCESSORY DRAWERS AND DOORS SINGLE DRAWER SINGLE 2- OR 3-DRAWER DOUBLE PAPER TOWEL DRAWER SHORT DRY STORAGE TALL DRY STORAGE TRASH/RECYCLING DRAWER 128 | Wolf Customer Care 800.222.
Outdoor Accessories Access Doors DIMENSIONS INSTALLATION 3 1/2" (89) B FINISHED RETURN 2 3/4" (70) W A 1" (25) min 20 3/4" 18 3/4" (527) (476) GRILL OPENING TOP VIEW 19" (483) OPENING HEIGHT W OPENING WIDTH DOOR WIDTH A B 18" Single 18" (457) 161/4" (413) 30" Double 30" (762) 281/4" (718) 36" Double 36" (914) 341/4" (870) 42" Double 42" (1067) 401/4" (1022) 54" Double 54" (1372) 521/4" (1327) FRONT VIEW OPENING WIDTH W 18" Single 161/2" (419) 30" Double 281/2" (724)
Outdoor Accessories Accessory Drawers and Doors SINGLE DRAWER 2- OR 3-DRAWER 27" (686) 12" (305) 24" 18" (610) (457) 2 3/4" (70) 2 3/4" (70) 30" (762) 13" (330) 11 3/8" 9 1/2" (289) (241) 20 3/4" 19" (527) (483) PAPER TOWEL DRAWER 14 1/2" (368) DRAWER/DOOR 28 1/2" (724) 19" (483) 18" 2 3/4" (70) (457) 18" (457) 2 3/4" (70) 10" (254) 130 | Wolf Customer Care 800.222.
Outdoor Accessories Accessory Drawers and Doors TALL DRY STORAGE TRASH/RECYCLING DRAWER 16" (406) 22" (559) 19 3/4" (502) D 2 3/4" (70) 2 3/4" (70) 24" (610) 18" (457) 34" 32" (864) (813) 26" 24" (660) (610) DEPTH SHORT DRY STORAGE 34" (864) D Single 19 1/2" (495) Double 22 1/2" (572) 19 3/4" (502) 2 3/4" (70) 36" (914) 20 3/4" 18 3/4" (527) (476) wolfappliance.
Outdoor Accessories Accessory Drawers and Doors INSTALLATION OPENING W H D 271/4" (692) 93/4" (248) 241/4" (616) Paper Towel Drawer 143/4 (375) 81/4" (210) 191/4" (489) 2- or 3-Drawer 121/4" (311) 191/4" (489) 181/4" (464) Drawer/Door 283/4" (730) 191/4" (489) 181/4" (464) Tall Dry Storage 221/4" (565) 321/4" (819) 20" (508) Short Dry Storage 341/4" (870) 19" (483) 20" (508) Single Trash/Recycling 161/4" (413) 241/4" (616) 193/4" (502) Double Trash/Recycling 161/4" (413) 24
Outdoor Accessories wolfappliance.
Cooktop Ventilation Hoods Cooktop Ventilation Hoods Wolf cooktop ventilation hoods feature three distinct looks—black, stainless, and glass. Brilliant LED lighting illuminates your cooking surface while powerful multi-speed blowers whisk away smoke and odors. Dishwasher-safe filters can be removed easily for cleaning. Wall-mount and island hoods are crafted of stainless steel.
Cooktop Ventilation Hoods Cooktop Hoods WALL HOODS—BLACK 11 3/4" 10 1/4" (298) (260) 29 1/8" (740) TO 39 1/4" (997)* 211/4" (540) 21/4" (57) W 19 1/4" WIDTH (489) *49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension. WIDTH W VW30B 30" (762) VW36B 36" (914) VW45B 45" (1143) ISLAND HOOD—BLACK 13 3/4" 111/4" (349) (286) 23 5/8" (600) TO 32" (813)* 23 1/4" (591) 21/4" (57) 42" 26 1/2" (1067) (673) *46 1/4" (1175) to 55" (1397) with accessory flue extension.
Cooktop Ventilation Hoods Cooktop Hoods WALL HOODS—STAINLESS 11 3/4" 10 1/4" (298) (260) 29 1/8" (740) 211/4" TO 39 1/4" (997)* (540) 6" (152) W 22" WIDTH (559) *49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension. WIDTH W VW30S 30" (762) VW36S 36" (914) ISLAND HOOD—STAINLESS 13 3/4" 111/4" (349) (286) 23 5/8" (600) 23 1/4" TO 32" (813)* (591) 6" (152) 42" 26 1/2" (1067) (673) *46 1/4" (1175) to 55" (1397) with accessory flue extension.
Cooktop Ventilation Hoods Cooktop Hoods WALL HOODS—GLASS 11 3/4" 10 1/4" (298) (260) 29 1/8" (740) TO 39 1/4" (997)* 211/4" (540) 21/4" (57) W 19 1/4" WIDTH (489) *49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension. WIDTH W VW36G 36" (914) VW45G 45" (1143) ISLAND HOOD—GLASS 13 3/4" 111/4" (349) (286) 23 5/8" (600) TO 32" (813)* 23 1/4" (591) 21/4" (57) 45" 26 1/2" (1143) (673) *46 1/4" (1175) to 55" (1397) with accessory flue extension. wolfappliance.
Cooktop Ventilation Hoods Planning Information Wolf cooktop ventilation hoods are recommended for use with Wolf induction, electric and gas cooktops, and modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended. These hoods have a telescopic chimney flue. A flue extension is available through an authorized Wolf dealer. Installation of the cooktop hood should be 24" (610) to 36" (914) from the bottom of the hood to the countertop.
Cooktop Ventilation Hoods Ceiling-Mounted Hood The ceiling-mounted hood is our most contemporary ventilation offering, nearly disappearing into its surroundings. It comes in two widths and is available in stainless steel or white glass. The hood ships with a remote control and can be operated using the remote control or the control panel. The control panel is recessed into the right side of the hood. The dishwasher-safe filters can be removed easily for cleaning.
Cooktop Ventilation Hoods Ceiling-Mounted Hood STAINLESS STEEL A 13 1/4" 13 1/4" (337) (337) 7 1/4" (184) TO 12 3/4" (324) 7 1/4" (184) 5" (127) 1/16" (2) W DIMENSIONS 21" (533) W A 36" Hood 351/2" (902) 331/8" (841) 48" Hood 471/4" (1200) 441/8" (1121) WHITE GLASS A 13 1/4" 13 1/4" (337) (337) 7 1/4" (184) TO 12 3/4" (324) 7 1/4" (184) 5" (127) 1/4" (6) W DIMENSIONS 21" (533) W A 36" Hood 351/2" (902) 331/8" (841) 48" Hood 471/4" (1200) 441/8" (1121) 140 | Wolf Custom
Cooktop Ventilation Hoods Planning Information Installation of the ceiling-mounted hood should be 36" (914) to 84" (2134) from the bottom of the hood to the countertop. The hood can be operated using the remote control or the control panel located on the right side of the hood. The hood is shipped without a blower assembly. Internal, in-line, and remote blowers are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.
Cooktop Ventilation Hoods Planning Information Opening Dimensions ELECTRICAL REQUIREMENTS CEILING-MOUNTED HOOD Installation must comply with all applicable electrical codes. Refer to the chart and illustrations below for opening dimensions and typical framing. Framing must be able to support a minimum of 100 lb (45 kg). Locate the electrical supply within the shaded area shown in the illustration below. Allow a minimum 12" (305) Romex® wire for connection.
Cooktop Ventilation Hoods Under-Cabinet Hood Insert The under-cabinet hood insert mounts inside a cabinet. It comes in two widths and is available in stainless steel. The hood ships with a remote control and can be operated using the remote control or the control panel. The dishwasher-safe filters can be removed easily for cleaning.
Cooktop Ventilation Hoods Planning Information The under-cabinet hood insert should be installed 24" (610) to 36" (914) from the bottom of the hood to the countertop. The hood can be operated using the remote control or the control panel located at the front of the hood bottom. The hood requires a 300 or 600 CFM internal blower, available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Cooktop Ventilation Hoods Planning Information Opening Dimensions ELECTRICAL REQUIREMENTS UNDER-CABINET HOOD INSERT Installation must comply with all applicable electrical codes. Refer to the chart and illustration below for opening dimensions. The cabinet must be able to support a minimum of 100 lb (45 kg). Locate the electrical supply above or in an adjacent cabinet within reach of the power cord. Refer to the illustration below. A separate circuit servicing only this appliance is required.
Downdraft Ventilation Downdraft Ventilation Constructed of heavy duty stainless steel, the Wolf downdraft rises from the countertop to whisk away odor and smoke into stainless steel, mesh filters and can be lowered beneath the countertop when not in use. Downdrafts integrate perfectly with transitional induction and electric cooktops, gas cooktops, and some modules, they can also be installed with certain sealed burner rangetops. 146 | Wolf Customer Care 800.222.
Downdraft Ventilation Downdraft Ventilation DIMENSIONS 2" W (51) DOWNDRAFT WIDTH 6 3/4" (172) 14" (356) 2 3/8" (60) 15" 13" (381) (330) 28 3/4" (730) 10" (254) 13" (330) A CHIMNEY WIDTH 2 1/2" (64) NOTE: Shown with front mounted internal blower with 6" (152) round discharge, dashed line represents rear mount. WIDTH W A DD30 30" (762) 261/2" (673) DD36 36" (914) 321/2" (826) DD45 45" (1143) 381/2" (978) wolfappliance.
Downdraft Ventilation Planning Information Wolf downdrafts can be installed with most Wolf cooktops, but are not compatible with the grill, steamer, and fryer modules. Downdrafts can be installed with sealed burner rangetop models SRT304 and SRT366. For installation with a Wolf cooktop, a minimum 251/8" (638) deep flat countertop is required. For installation with a sealed burner rangetop or 30" (762) or 36" (914) contemporary cooktop, an accessory trim kit is required.
Downdraft Ventilation Downdraft INSTALLATION WITH STANDARD INSTALLED COOKTOP W DOWNDRAFT CUTOUT WIDTH 2 11/16" (68) E 8 1/4" (210)* COOKTOP CUTOUT TOP VIEW 8 1/4" (210)* 211/4" 211/4" 23 3/8" (540) (540) (594) E SIDE VIEW FRONT VIEW *6" (152) back from countertop cutout when internal blower is rear mounted. NOTE: Internal blower 6" (152) round, side, rear or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cutout.
Downdraft Ventilation Downdraft INSTALLATION WITH FLUSH INSTALLED COOKTOP W DOWNDRAFT CUTOUT WIDTH 2 5/16" (59) E 8 1/4" (210)* COOKTOP CUTOUT TOP VIEW 8 1/4" (210)* 211/4" 211/4" 23 3/8" (540) (540) (594) E SIDE VIEW FRONT VIEW *6" (152) back from countertop cutout when internal blower is rear mounted. NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cutout.
Downdraft Ventilation Downdraft INSTALLATION WITH SEALED BURNER RANGETOP W DOWNDRAFT CUTOUT WIDTH 2 11/16" (68) E 8 1/4" (210)* RANGETOP OPENING TOP VIEW 19" (483) PLATFORM DEPTH 211/4" 211/4" 23 3/8" (540) (540) (594) 8 1/4" (210)* E SIDE VIEW FRONT VIEW *6" (152) back from countertop cutout when internal blower is rear mounted. NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Pro Ventilation Hoods Pro Ventilation Hoods Professional heritage shines through in Wolf professional-style ventilation. Exteriors are heavy-duty, welded stainless steel, so finely hand-finished they appear seamless. Pro hoods are available in a variety of widths. Stainless steel baffle filters and halogen lighting extend the professional look and back it up with pro-level performance. All pro ventilation hoods are crafted of stainless steel. A hood liner is also available for custom applications.
Pro Ventilation Hoods Pro Hoods LOW-PROFILE WALL HOOD 12" (305) 10" (254) 4" (102) 22" (559) W WIDTH 24" DEEP WALL HOOD 12" (305) 18" (457) 4" (102) 24" (610) W WIDTH 27" DEEP WALL HOOD 12" (305) 18" (457) 4" (102) 27" (686) W WIDTH WIDTH LOW-PROFILE WALL HOOD W 30" (762), 36" (914), 42" (1067), 48" (1219) 24" DEEP WALL HOOD W 30" (762), 36" (914), 42" (1067), 48" (1219) 54" (1372), 60" (1524), 66" (1676) 27" DEEP WALL HOOD W 30" (762), 36" (914), 42" (1067), 48" (1219) 54" (1372), 60
Pro Ventilation Hoods Pro Hoods WALL CHIMNEY HOOD 13 1/2" WIDTH MINUS 18" (457) (343) 18" (457) 4" (102) 24" (610) W WIDTH ISLAND HOOD WIDTH MINUS 18" (457) 13" (330) 18" (457) 4" (102) 34" (864) W WIDTH HOOD LINER 12" WIDTH MINUS 6" (152) (305) 12 1/8" (308) 4" (102) 19 3/8" (492) 22 5/8" (575) W WIDTH WIDTH WALL CHIMNEY HOOD W 36" (914), 42" (1067), 48" (1219), 54" (1372) ISLAND HOOD W 36" (914), 42" (1067), 54" (1372), 66" (1676) HOOD LINER W 343/8" (873), 403/8" (1026), 463/8" (
Pro Ventilation Hoods Pro Hoods OUTDOOR WALL HOOD 13 9/16" (346) 18" (457) 4" (102) 33" (838) W WIDTH WIDTH OUTDOOR WALL HOOD W 36" (914), 48" (1219), 60" (1524) wolfappliance.
Pro Ventilation Hoods Planning Information Pro ventilation hoods and hood liners are recommended for use with all Wolf cooking appliances. Wall hoods should be at least as wide as the cooking surface and island hoods should be 3" (76) wider on each side. For optimal performance in wall hood applications, a pro 27" deep wall hood is recommended for use with ranges and rangetops with a charbroiler or griddle.
Pro Ventilation Hoods Installation LOW-PROFILE / 24" DEEP / 27" DEEP WALL HOOD E 6" (152) 5" (127) 30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP OUTDOOR WALL HOOD E 6" (152) 5" (127) 36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP WALL CHIMNEY HOOD E 6" (152) 5" (127) 30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP ISLAND HOOD ELECTRICAL LOCATION THROUGH TOP OF HOOD 30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP HOOD LINER DECORATIVE HOOD E 121/2" (318) 75/8" (194) 30" (76
Ventilation Suggestions Blower Assemblies For Wolf ventilation hoods and downdrafts that do not include a blower assembly, an internal, in-line, or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements, and homeowner preferences. Internal, in-line, and remote blowers are avail able through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Ventilation Suggestions Wolf Product CFM CFM COOKTOP HOOD DOWNDRAFT PRO HOOD CI152TF/S CE152TF/S CG152TF/S 300 600 300 SM15TF/S FM15TF/S GM15TF/S 300 TM15TF/S MM15TF/S 300 CI243TF/S CI243C/B CG243TF/S 300 CI304TF/S CI304T/S CI304C/B 300 600 300 CE304T/S CE304C/B 300 600 300 CG304T/S CG304P/S 300 600 300 CI365TF/S CI365T/S CI365C/B 300 600 300 CE365T/S CE365C/B 300 600 300 CG365T/S CG365P/S CG365C/S 300 600 300 COOKTOP / MODULE 300 600 300 300 DUAL FUEL RANGE DF3045
Ventilation Suggestions Wolf Ventilation Blower Options INTERNAL BLOWER (CFM) 300 INT* 400 INT* 500 INT 600 INT 800 INT 1200 INT COOKTOP HOOD VW30B VW36B VW45B VI42B • • VW30S VW36S VI42S • • VW36G VW45G VI45G • • CEILING-MOUNTED HOOD VC36S VC36W VC48S VC48W • UNDER-CABINET HOOD INSERT VU24S VU30S • • DOWNDRAFT DD30 DD36 DD45 • PRO LOW-PROFILE WALL HOOD PW302210 PW362210 • PW422210 PW482210 • PRO 24" WALL HOOD PW302418 PW362418 PW422418 • • • • • PW482418 PW542418 •
Ventilation Suggestions Wolf Ventilation Blower Options IN-LINE / REMOTE BLOWER (CFM) 600 IL 1100 IL 600 REM 900 REM 1200 REM 1500 REM COOKTOP HOOD VW30B VW36B VW45B VI42B • • VW30S VW36S VI42S • • VW36G VW45G VI45G • • • • • • • • • CEILING-MOUNTED HOOD VC36S VC36W VC48S VC48W UNDER-CABINET HOOD INSERT VU24S VU30S DOWNDRAFT DD30 DD36 DD45 PRO LOW-PROFILE WALL HOOD PW302210 PW362210 • • • • • • PW422210 PW482210 • • • • • • PW302418 • • • • • • PW362418 PW42
Warranty Wolf Appliance Residential Limited Warranty FOR RESIDENTIAL USE FULL TWO YEAR WARRANTY* For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship.
Warranty Wolf Appliance Outdoor Limited Warranty* FOR RESIDENTIAL USE FULL ONE YEAR WARRANTY** For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship.
WOLFAPPLIANCE.