Installation Guide
FLUSH MOUNT INSTALLATION MANUAL - 3©
2018 IRONRIDGE, INC. VERSION 1.60
CHECKLIST
PRE-INSTALLATION
☐ Verify module compatibility. See Page 9 for info.
TOOLS REQUIRED
☐ Cordless Drill (non-impact)
☐ Impact Driver (for lag bolts)
☐ Torque Wrench (0-250 in-lbs)
☐ 5/16” Socket
☐ 7/16” Socket
☐ 1/2" Socket
☐ String Line
TORQUE VALUES
☐ FlashFoot2 Lag Bolts (7/16" Socket): Fully seat
☐ Bonded Splice Screws (5/16" Socket): 20 in-lbs
☐ Grounding Lug Nuts (7/16" Socket): 80 in-lbs
☐ Grounding Lug Terminal Screws (7/16 Socket): 20 in-lbs
☐ Universal Fastening Object (7/16" Socket): 80 in-lbs
☐ Expansion Joint Nuts (7/16" Socket): 80 in-lbs
☐ Flush Standoffs (1/2" Socket): 140 in-lbs
☐ Microinverter Kit Nuts (7/16" Socket): 80 in-lbs
☐ Frameless Module Kit Nuts (7/16" Socket): 80 in-lbs
☐ 3/8" Bonding Hardware Kit Nuts (7/16" Socket): 250 in-lbs
í If using previous version of: FlashFoot, Integrated Grounding
Mid Clamps, Grounding Lug, End Clamps, and Expansion Joints
please refer to Alternate Components Addendum (Version 1.20).
IRONRIDGE COMPONENTS
End Cap
XR Rail L-Foot
Bonded Splice
Stopper Sleeve
Wire Clip Flush Standoff
UFO
Frameless
Module Kit
Microinverter Kit
Grounding Lug
Expansion Joint
FlashFoot2
3/8" Bonding
Hardware Kits
Frameless
Mid Clamp
Frameless
End Clamp