Installation Guide

www.canadiansolar.com
| 
13
Use four clamps on the short side.
Use four clamps on the short side and two clamps
on the long side. An additional support bar
should be placed below the center of the module.
A2 range = (0 – 210) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A2 range = (170 – 210) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2
A2A2
A2
A2
A2A2
A2
Use four clamps on the long side. Mounting rails
run parallel to the long side frame.
A1
A1 A1
A1
A1 range = (240 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
A3
A3 A5
A5
Use six clamps on the long side. Mounting rails
run perpendicularly to the long side frame.
A3 range = (80 –380) mm
A5 range = (80 –380) mm
Maximum Load:
Uplift load ≤ 4000 Pa
Downforce load ≤ 6000 Pa
A4A4
A4A4