Installation Guide

o
Limit:Limitationsetting(ExportorProduction)
o
Inverters:Numberofconnectedinvertersinthecluster,includingthemaster.
Communication Status
Thisscreendisplaysthestatusofconnectionoption(s):LAN,RS485,cellularorZigBeePlug-in.
Communication
LAN
Connected
RS485-1
SE Slave
NC
RS485-2
Modbus
2 of 2
Cellular
N/A
Wi-Fi
NC
ZigBee
NC
Foreachcommunicationoption,oneofthefollowingstatusesisdisplayed:
l Connected:Theinverterestablishedasuccessfulconnectionandcommunicationwiththespecified
serverport
l NC:NotConnected.RefertoTroubleshootingCommunicationonpage56
l S_OK:Theconnectiontothemonitoringplatformissuccessful(shouldappearonlyiftheisconnected
totheserver)
l N/A:NotApplicable
l x of y:Numberofdevicesconnectedoutofalldevices
l
Temporarilydisplayed(witha clocksign):
o
Initializing communication
o
Connectingtoanetwork
o
ConnectingtoSolarEdgeservers
l
Error message(withthe
sign).RefertoTroubleshootingCommunicationonpage56.
Inverter Energy Status
Displaysthetotalenergyproducedduringthelastday,month,yearandsinceinverterinstallation.
InverterEnergy
Today
45 kWh
This Month
1.14 MWh
This Year
13.68 MWh
Total: 41.03 MWh
l Today:sincemidnight
l This Month:since1stofthecurrentmonth
l This Year:sinceJanuary1st
l Total (Wh):Theinvertertotalenergy.Ifanexternalmeterisinstalled,thevaluedisplayedinthisline
dependsonthemetertypeconnectedtotheinverteranditslocation:
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
40