Installation Guide
2.
Toallowproperheatdissipation,maintainthefollowingminimumclearanceareasbetweenthe
inverterandotherobjects:
Figure 16: Clearance areas
3. Positionthemountingbracketagainstthewall/poleandmarkthedrillingholelocations(referto
MechanicalSpecificationsonpage58forinverterandmountingbracketdimensions).
4.
Drilltheholesandmountthebracket.Verifythatthebracketisfirmlyattachedtothemounting
surface.
5.
Hangtheinverteronthebracket:
a. Lifttheinverterfromthesides,orholditatthetopandbottomoftheinvertertolifttheunitinto
place.DonotliftholdingtheSafetySwitchasitmaybedamaged.
b. LowertheinverterontotheU-shapedindentations,asshownbelow.Lettheinverterlayflat
againstthewallorpole.
c.
Insertthetwosuppliedscrewsthroughtheouterheatsinkfinonbothsidesoftheinverterand
intothebracket.Tightenthescrewswithatorqueof4.0N*m/2.9lb.*ft.
Figure 17: Hanging the inverter on the brackets
Chapter 3: Installing the Inverter
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
27