Installation Manual

Appendix C: Replacing and Adding System
Components
NOTE
If you are permanently disassembling the installation or part of it, make sure to use the disposal
methods dictated by local regulations.
Fuse Replacement
Theinverterisequippedwithafuse,locatedatthetoprightcorneroftheinverter.
FusereplacementkitsareavailablefromSolarEdgeoryoucanuseotherfuseswithidenticalratings.
1. TurnOFFtheinverterON/OFFswitch,andwaituntiltheLCDindicatesthattheDCvoltageissafe
(<50V),orwaitfiveminutesbeforecontinuingtothenextstep.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
AVERTISSEMENT!
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement est indiqué sur l'écran
LCD, attendez cinq minutes pour que les condensateurs d'entrée de l'onduleur soient déchargés.
2. TurnOFFtheDCSafetyUnit.
3. Openandremovetheinvertercover.
4. Removetheexistingfusefromtheuppercorneroftheinverterandreplacewithanewfuse.
5.
Closetheinvertercover.
Figure 35: Inverter fuse
6.
TurnON:
l TheinverterON/OFFswitch
l TheDCSafetyUnit
7. Verifypropersystemoperation.
Appendix C: Replacing and Adding System Components
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
73