Installation guide

WithL.Rgas,pipingortubingsizecanbe
1/2"minimum.Asmallersizepipeon
longerrunsmayresultininsufficientgas
supply.Usually,L.Rgassuppliers
determinethesizeandmaterialsusedin
thesystem.
Pipe-jointcompoundsmadefor usewith
L.Rgasmustbeusedonpipethreadsonly.
Flexible metal applianceconnector: If
local codes permit, a new CSA design-
certified, 1/2" or 3/4" I.D., flexible metal
appliance connector is recommended for
connecting range to the gas supply line.
A 1/2" male pipe thread nipple is needed
for connection to pressure regulator
connection fitting. Do Not kink or
damage the flexible metal tubing when
moving the range.
Rigid pipe connection: Requires a
combination of pipe fittings to obtain an
in-line connection to the range. All strains
must be removed from the supply and
fuel lines so range will be level and in
line.
Shutoff valve:The supply line must be
equipped with a manual shutoff valve.
This valve should be located in the same
room as the range and should be in a
location that allows ease of opening and
closing.The valve is for turning on or
shutting off gas to the range. Do Not
block access to shutoff valve.
Pressure regulator:The gas pressure
regulator supplied with this range must
be used.The inlet pressure to the
regulator should be as follows for proper
operation:
NATURAL GAS:
Minimum pressure: 5 [nchesW.C.
Maximum pressure: 14 inchesW.C.
L.RGAS:
Minimum pressure: 11inchesW.C.
Maximum pressure: 14 inchesW.C.
Contact local gas supplier if you are not
sure about the inlet pressure.
Line pressuretesting above 1/2 psi
(3.5 kPa) or 14" W.C. (35.5 cm) (gauge} --
The range and its individual manual
shutoff valve must be disconnected from
the gas supply piping system during any
pressure testing of that system at test
pressures greater than 1/2 psig (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa)
or 14" W.C. (35.5 cm) (gauge} or lower --
The range must be isolated from the gas
supply piping system by closing its
individual manual shutoff valve during
any pressure testing of that system at
test pressures equal to or less than 1/2
psig (3.5 kPa).
Copies of the standards listed may be obtained
from:
CSA international
8501 East PleasantValley Road
Cleveland, Ohio 44131-5575
Now start...
Excessive Weight Hazard
Use two or more people to move
and install range.
Failure to do so can result in back
or other injury.
[] Put on safety glasses and gloves.
Do Not use oven door handle to lift or
move the range.
[] Remove oven racks and parts
package from inside oven. Remove
shipping materials, tape and protective
film from range.
shipping base
[] Keep cardboard shipping base
under range to prevent damage to floor
covering.
Tip Over Hazard
A child or adult can tip the range
and be killed.
Connect anti-tip bracket to rear
range foot.
Reconnect the anti-tip bracket, if
the range is moved.
Failure to follow these instructions
can result in death or serious
burns to children and adults.
Contact a qualified floor covering
installer for the best procedure for
drilling mounting holesthrough your type
floor covering.
., Use the anti-tip bracket
template/instruction sheet to
install the anti-tip bracket.
Anti-tip bracket must
be anchored
securely to the
sub floor.
Depending on
the thickness of
your flooring,
longer screws
may be needed to
anchor the bracket to the sub
floor. Longer screws are available from
your local hardware store.
[] Check that range is still on
cardboard shippingbase to protect floor
covering. Move range close to final
location.
front
leveling leg
-_ ivaerffng leg%
pping
base from under range. Open broiler
door. Use a 3/8" drive ratchet to lower
rear leveling legs one-half turn. Use
slip-joint pliers to lower front leveling
legs one-half turn.