Installation guide

Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these
instructions can result in death,
fire, or electrical shock.
if codespermit and a separate ground
wire is used, it isrecommended that a
qualified electrician determine that the
ground path is adequate.
Do Not ground to a gas pipe.
Checkwith a qualified electrician if
you are not sure range isproperly
grounded.
A 120-vok, 60-Hz, AC-only, 10-ampere,
fused electrical supply is required. A
time-delay fuse or circuit breaker is
recommended. It is recommended that
a separate circuit serving only this
appliance be provided.
Electronic ignition systems operate
within wide voltage limits, but proper
grounding and polarity are necessary.
In addition to checking that the outlet is
correctly grounded, the outlet must be
checked by a qualified electrician to
see if it is wired with correct polarity.
important: This range is equipped
with an electronic ignition system that
will not operate if plugged into an
outlet that is not properly polarized.
A wiring diagram is included on the
back of the range.
See "Cabinet dimensions/
requirements," Page 3, for
recommended location of electrical
outlet.
Page 4
Recommended
groundmethod
For personal safety, this range is
equipped with a power supply cord
having a 3-prong ground plug. To
minimize possible shock hazard, the
cord must be plugged into a
mating 3-prong, ground-type outlet,
grounded in accordance with the
National Electrical Code, ANSl/NFPA 70
-- latest edition* or CSA Standard
C22.1, Canadian Electrical Code, Part 1,
-- latest edition** and all local codes
and ordinances.
If a mating outlet is not available, it is
the personal responsibility and
obligation of the customer to have a
properly polarized and grounded,
3-prong outlet installed by a qualified
electrician.
Copies of the standards listed may be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
_ CSA international
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
3-prong ground
plug
/
power supply
cord
I_ I_ polarized
I II ground-type
_ outlet
Explosion Hazard
Use a new AGA or C8A approved
gas supply line.
Install a shut-off valve.
8ecurely tighten all gas
connections.
If connected to LP, have a qualified
person make sure gas pressure
does not exceed 14" water column.
Examples of a qualified person
include licensed heating personnel,
authorized gas company personnel,
and authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
Observe all governingcodes and
ordinances.
This installation must conform with
local codes and ordinances. In the
absence of local codes, installations
must conform with American National
Standard, National Fuel Gas Code
ANSI Z223.1 -- latest edition* or
CAN/CGA-B149- latest edition*
installationcodes.
Input ratings shown on the
model/serial rating plate are for
elevations up to 2,000 feet. For
assistance when installing the range at
higher elevations, contact your local
service company.
Type of gas: This range is design-
certified by CSA International for use
with Natural gas or, after proper
conversion, for use with L. P. gas. This
range isfactory set for use with Natural
gas. Gas conversion instructions are
provided on pages 8-10. The
model/serial rating plate located on the
frame behind the broiler drawer has
information on the type of gas that can
be used. If the type of gas listed does
not agree with the type of gas
available, check with the local gas
supplier. Conversion must be done by
a qualified service technician.