Attach Mounting Plate to Wall
1. Position mounting plate on the wall.
NOTE: It may be necessary to use a number of the spacers,
between the mounting plate and the wall, to achieve a more
‘Flush’ appearance. Stick spacers before position mounting
plate on the wall.
Measure from the back wall to where the front bottom surface
of the microwave oven needs to be to determine the number
of spacers needed.
B
A
A. Mounting Plate
B. 1/16" (1.6 mm) thickness
Depth of cabinet Mounting plate
12" to 13"
(30.5 cm to 33 cm)
Mounting plate
13
1
/
16
" (33.2 cm) Mounting plate + 4 pieces of
spacer
13
1
/
8
" (33.3 cm) Mounting plate + 8 pieces of
spacer
2. Secure the mounting plate to the wall at both end holes drilled
into the wall studs and/or drywall using either 3/16-24 x 3"
round-head bolts and toggle nuts or 1/4 x 2" lag screws.
Refer to illustrations in “Possible Wall Stud Configurations” in
the “Locate Wall Stud(s)” section, and the following sections
“No Wall Studs at End Holes (Figures 1 and 2 in Find the Wall
Stud(s) section)” or Wall Stud at One End Hole (Figure 3 in
Find the wall Stud(s) section)” .
3. Insert lag screws into both end holes.
4. Check alignment of mounting plate, making sure it is level.
5. Secure the two end hole screws.
6. Secure the mounting plate to the wall at both H & J holes
using two 1/4 x 2" lag screws.
A
B
A. Mounting Plate
B. H & J holes
No Wall Studs at End Holes (Figures 1 and 2 in
Find the Wall Stud(s) section)
NOTE: The mounting plate must be secured to the wall on at
least 1 wall stud as well as at both ends.
1. With the support tabs of the mounting plate facing forward,
insert 3/16-24 x 3" round-head bolts through both end holes of
mounting plate.
2. Start toggle nuts on bolts from the back of the mounting plate.
Leave enough space for the toggle nuts to go through the wall
and to open.
A
B
C
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
3. Position mounting plate on the wall.
4. Push the 2 bolts with toggle nuts through the drywall, and
finger tighten the bolts to make sure toggle nuts have opened
against drywall.
A
B
C
D
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
D. Drywall
5. Insert lag screw(s) into the hole(s) drilled into wall stud(s) in
Step 2 of “Installation for No Wall Studs at End Holes” in the
“Drill Holes in Rear Wall” section.
6. Check alignment of mounting plate, making sure it is level.
7. Securely tighten all lag screws and bolts.