User's Manual

®
PRODUCT MODEL NUMBERS
GGN2000H
GGQ9858J
LGC8858E
LGN1000H
LGQ8800J
LGQ8857H
LGQ8857J
LGQ8858H
LGQ8858J
LGR3624E
LGR3624J
LGR3634E
LGR3634J
LGR4634E
LGR5600H
LGR5600J
LGR5636E
LGR5636J
LGR5644E
LGR5644J
LGR5848E
LGR7646J
LGR8857E
LGR8858E
LGT7646E
LGW8858H
Gas supply: Dryer is equipped for use with
NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. Pipe-joint
compounds resistant to the action of L.P. gas must
be used. If local codes permit, it is recommended
that new flexible metal tubing, design-certified by
AGA or CSA, be used for connecting the appliance
to the rigid gas supply line. (The gas pipe which
extends through the lower rear of the appliance
has 3/8-inch male pipe thread.) An individual
manual shutoff valve must be installed within 6
feet of the dryer in accordance with the National
Fuel Gas Code ANSI Z223.1.
Electrical: 120-volt, 60-Hz,
AC-only, 15- or 20-amp.
electrical supply. Use copper
wire only. A time-delay fuse
or circuit breaker and
separate circuit is
recommended.
Exhaust venting: Exhaust
your dryer to the outside.
four-inch diameter vent is
required. Rigid or flexible
metal exhaust vent must be
used. Do Not use plastic or
metal foil vent. Exhaust outlet
hood must be at least 12
inches from the ground or
any object that may be in the
path of the exhaust.
Gas Dryer
OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
Closet confined area
Select the route that will provide the straightest and most direct path outdoors. Plan the
installation to use the fewest number of elbows and turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible. Bend flexible
metal vent gradually to avoid kinking.
Determine vent length
1. See the exhaust vent length chart that matches your type hood for the maximum vent
lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using (rigid or flexible), find the
maximum length of metal vent on the same line as the number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and a 2-1/2"
exhaust hood is 8 ft.
3"
3"
48 sq. in.
*
24 sq. in.*
14"
max.
front view
1"
closet
door
* Minimum top and bottom air openings for closet door.
**External exhaust elbow requires additional space.
0"***
0"***
front view
18"
If a closet door is installed: The minimum unobstructed
air openings are required. Louvered doors with equivalent
air openings are acceptable.
***Wall, door and floor molding
may require additional spacing.
side view
Recessed
area
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3405338 Rev. D
01-09-03
4"
**
DOOR CLEARANCE
DIMENSIONS
Large side-swing
door (reversible)
17-3/4"
22-3/4"
22-3/4"
7"
Extra-large hamper door
Small side-swing door
15-1/4"
15-1/4"
15-1/4"
13-3/4"
13-3/4"
25-5/8"
8-1/4"
8-3/4"
22-3/4"
22-3/4"
19-1/8"
Super-large
side-swing door (reversible)
3-7/8"
* from floor with dryer feet extended 1 inch
** Most installations will require at least 5-inch clearance
behind the dryer for the dryer vent.
29"
28" max.**
14-1/2"
9-1/4"
6"*
2-1/8"
42-3/8"*
gas burner inlet
pipe connection
at rear of dryer
dryer exhaust
vent
4"
4"
Preferred
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 4" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
64 ft.
54 ft.
44 ft.
35 ft.
27 ft.
36 ft.
31 ft.
27 ft.
25 ft.
23 ft.
Acceptable
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
58 ft.
48 ft.
38 ft.
29 ft.
21 ft.
28 ft.
23 ft.
19 ft.
17 ft.
15 ft.
2-1/2"