Owner's Manual
Table Of Contents
- Dryer Safety
- Dryer Safety
- Dryer Maintenance and Care
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Changing the Drum Light (on some models)
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- Special Instructions for Steam Models
- Installation Instructions
- Requirements
- Tools and Parts
- Location Requirements
- Gas Dryer Power Hookup – U.S.A. and Canada
- Gas Supply Requirements
- Installation
- Install Leveling Legs
- Make Gas Connection – U.S.A. and Canada
- Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Inlet Hoses
- Connect Vent
- Level Dryer
- Complete Installation Checklist
- Sécurité de la sécheuse
- Sécurité de la sécheuse
- Entretien et réparation de la sécheuse
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Changement de l’ampoule d’éclairage du tambour (sur certains modèles)
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre avant des vacances, un entreposage ou un déménagement
- Instructions spécifiques pour les modèles vapeur
- Instructions d’installation
- Spécifications
- Outils et pièces
- Exigences d’emplacement
- Raccordement électrique de la sécheuse à gaz - états-unis et canada
- Spécifications de l’alimentation en gaz
- L’installation
- Exigences d’emplacement
- Raccordement au gaz - états-unis et canada
- Exigences concernant l’évacuation
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement des tuyaux d’alimentation
- Raccordement du conduit d’évacuation
- Réglage de l’aplomb de la sécheuse
- Liste de vérification pour installation terminée
16
5. Attach long hose to dryer fill valve and tighten
coupling
If applicable, remove protective cap from water inlet valve.
Attach other end of long hose to fill valve on dryer back panel.
Screw on coupling by hand until it is seated on fill valve
connector. Using pliers, tighten the couplings an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can
result.
6. Turn on cold water faucet
Check that the water faucet is turned on.
7. Check for leaks
Check for leaks around “Y” connector, faucets, and hoses.
Connect Vent
1. Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect the vent to exhaust
outlet in the dryer. If connecting to existing vent, make sure
vent is clean. Dryer vent must fit over dryer exhaust outlet
and inside exhaust hood. Check that vent is secured to
exhaust hood with a 4" (102 mm) clamp.
2. Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under dryer.
Level Dryer
1. Level Dryer
Check levelness of dryer from side to side. Repeat from front
to back.
NOTE: The dryer must be level for the moisture-sensing
system to operate correctly.