Installation Guide
19
5. Attach long hose to dryer ll valve
and tighten coupling
Gas Valve
Fill Valve
Attach other end of long hose
to ll valve at bottom of dryer
back panel. Screw on coupling
by hand until it is seated on ll
valve connector. Using pliers,
tighten the couplings an additional
two-thirds turn.
NOTE: Do not overtighten.
Damage to the coupling can result.
Turn on cold water faucet
6.
Check that the water faucet is turned on.
Check for leaks
7.
Check for leaks around “Y” connector, faucets, and hoses.
CONNECT VENT
1. Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is clean.
Dryer vent must t over dryer exhaust outlet and inside exhaust
hood. Check that vent is secured to exhaust hood with a
4" (102 mm) clamp.
Move dryer to nal location
2.
Move dryer to nal location. Avoid crushing or kinking vent.