Installation Guide

Table Of Contents
9
Electrical Connection — U.S.A. Only
Power Supply Cord
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull the cover down and toward you to remove
cover from range.
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws
A. UL Listed strain relief
Tighten strain relief screw against the power supply cord.
3. Depending on your model, remove the plastic tag holding
three 10-32 hex nuts from the middle post of the terminal
block.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A
B
C
4. Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL Listed strain relief in the opening.
A
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
Direct Wire
REMOVE PLASTIC TAG AND
PLACE NUTS ONTO THE BLOCKS