Installation Instruction

6
INSTALLATION INSTRUCTIONS
Unpack Range
1. Remove shipping materials, tape and lm from range.
2. Remove oven racks and parts package from inside oven.
3. Do not remove the shipping base at this time.
4. On Ranges Equipped with a Storage Drawer:
Remove the storage drawer. See the “Storage Drawer”
section. Use a 1/4" (6.4 mm) drive ratchet to lower the rear
leveling legs one-half turn. Use a wrench or pliers to lower
front leveling legs one-half turn.
On Ranges Equipped with a Warming Drawer or Premium
Storage Drawer:
On ranges equipped with a warming drawer or premium
storage drawer, the rear legs cannot be accessed by
removing the warming drawer or premium storage drawer. It
will be necessary to adjust the rear legs from outside the
range. Use wrench or pliers to lower the front and rear
leveling legs one half turn.
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
A
A. Shipping base
C
D
A
B
A. 1/4" (6.4 mm) drive ratchet
B. Rear leveling leg
C. Wrench or pliers
D. Front leveling leg
B
C
A
A. Rear leveling leg
B. Wrench or pliers
C. Front leveling leg
Electrical Requirements - Canada Only
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualied electrical installer if you are not sure
the range is properly grounded.
Range Rating* Specied Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 V 120/208 V Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with
kit. For 50 A rated cord kits, use kits that specify use with a
nominal 1
3
/
8
" (3.5 cm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certied
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s nal location.
Do not use an extension cord.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.