Dimension Guide

Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W11508844A
04/19/2021
Page 1 of 2
30" (76.2 cm) Slide-in Gas Range
PRODUCT MODEL NUMBERS
WEG515S0L
GAS SUPPLY REQUIREMENTS
Gas supply line:
Provide a gas supply line of
3
/
4
" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be
1
/
2
" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long,
1
/
2
" (1.3 cm) or
3
/
4
" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
A
1
/
2
" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the
range.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
A
B
C
A. Gas supply line
B. Shutoff valve “open” position
C. To range
PRODUCT DIMENSIONS
This manual covers several models. Your model may appear different
from the models depicted. Dimensions given are maximum dimensions
across all models.
IMPORTANT:
Range must be level after installation. Follow the
instructions in the “Level Range” section of the Owner's Manual.
Using the cooktop as a reference for leveling the range is not
recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
Type of Gas
Natural gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section of the Owner's Manual. The model/serial rating
plate located behind the
control panel has information on the types of
gas that can be used. If the types of gas listed do not include the type
of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt
shall be made to convert the appliance from the gas specifi
ed on the
model/serial rating plate for use with a different gas without consulting
the serving gas supplier. See “Gas Conversions” section of the
Owner's Manual.
A
B
D
E
F
C
A. 1
3
/
16
" (3.0 cm) height from
cooktop to top of vent
B. 29
7
/
8
" (75.9 cm)
C. Model/serial number plate
(located behind the oven
door on the top right-hand
side of the oven frame)
D. 36" (91.4 cm) height to
top of cooktop edge with
leveling legs screwed all the
way in*
E. 28
25
/
64
" (72.1 cm) max. depth
from front of console to back
of range.
F. 29
1
/
64
" (73.7 cm) max. depth
from handle to back of
range.
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The
inlet pressure to the regulator should be as follows for proper operation:
Natural gas:
Minimum pressure: 6" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 12" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
®