Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound on
threads of all non-ared male ttings. If exible metal tubing is
used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
®†
tape.
B
A
D
C
Plan pipe tting connection
2.
A. 3/8" exible gas connector
B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-are adapter tting
A combination of pipe ttings must be used to connect dryer to
existing gas line. Recommended connection is shown. Your
connection may be different, according to supply line type, size,
and location.
Open shut-off valve
3.
A
B
Open valve
Closed valve
Open shut-off valve in supply line; valve is open when handle is
parallel to gas pipe. Then, test all connections by brushing on
an approved noncorrosive leak-detection solution. Bubbles will
show a leak. Correct any leaks found.
MAKE GAS CONNECTION - U.S.A. AND CANADA
Connect gas supply to dryer
1.
A
B
Non-ared
male tting
Flared
male tting
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.