Owner's Manual
Table Of Contents
- DISHWASHER MAINTENANCE
- Dishwasher Loading Tips
- DISHWASHER care
- Dishwasher Setting Menu:
- ERROR CODES
- INSTALLATION REQUIREMENTS
- Installation Instructions
- Prepare cabinet opening— new utilities
- INSTALL OPTIONAL Moisture barrier - recommended for wood countertops
- ELECTRICAL CONNECTION
- PREPARE DISHWASHER
- Remove access panel and insulation
- DISCONNECT AND REMOVE DRIP tray ASSEMBLY
- CONNECT WATER LINE TO FILL VALVE
- CONNECT FILL HOSE TO FILL VALVE
- DRAIN HOSE CONNECTION
- Power cord Connection
- install DOOR HANDLE (ON SOME MODELS)
- PLACE DISHWASHER IN CABINET
- CUSTOM PANEL INSTALLATION (CUSTOM PANEL MODELS ONLY)
- Choose Anchor Attachment Method
- FINAL INSTALLATION CHECK
- SECURE DISHWASHER IN CABINET OPENING
- CONNECT WATER LINE TO HOUSE SHUT-OFF VALVE
- CONNECT DRAIN HOSE
- Complete Installation
- Check operation
- Install Access Panels
- if dishwasher does not operate
- ENTRETIEN DU LAVE-VAISSELLE
- Conseils de chargement du lave-vaisselle
- ENTRETIEN DU LAVE-VAISSELLE
- Menu de réglage du lave-vaisselle :
- CODES D’ANOMALIES
- EXIGENCES D’INSTALLATION
- Instructions d’installation
- Préparation de l’ouverture d’encastrement de l’armoire – nouveaux raccordements de service
- Installer la barrière anti-humidité en option – recommandée pour les comptoirs en bois
- RACCORDEMENT ÉLECTRIQUE
- PRÉPARATION DU LAVE-VAISSELLE
- Retrait du panneau d’accès et de l’isolation
- DÉBRANCHER ET ENLEVER LE PLATEAU D’ÉCOULEMENT
- BRANCHEMENT DE L’ARRIVÉE D’EAU À LA VALVE DE DISTRIBUTION
- BRANCHEMENT DU TUYAU DE REMPLISSAGE À LA VALVE DE DISTRIBUTION
- RACCORD DU TUYAU DE VIDANGE
- Branchement du cordon d’alimentation
- INSTALLER LA POIGNE DE PORTE (SUR CERTAINS MODÈLES)
- PLACER LE LAVE-VAISSELLE DANS L’ARMOIRE
- INSTALLATION DU PANNEAU PERSONNALISÉ (MODÈLES AVEC PANNEAU PERSONNALISÉ SEULEMENT)
- Choix de l’option de fixation
- VÉRIFICATION FINALE DE L’INSTALLATION
- FIXATION DU LAVE-VAISSELLE DANS L’OUVERTURE D’ENCASTREMENT DE L’ARMOIRE
- BRANCHEMENT DE L’ARRIVÉE D’EAU AU ROBINET D’ARRÊT DE LA MAISON
- RACCORDEMENT DU TUYAU DE VIDANGE
- Terminer l’installation
- Contrôle du fonctionnement
- Installation des panneaux d’accès
- Si le lave-vaisselle ne fonctionne pas
- MANTENIMIENTO DE LA LAVAVAJILLAS
- Consejos para cargar la lavavajillas
- Cuidado DE LA LAVAVAJILLAS
- Menú de ajustes de la lavavajillas:
- CÓDIGOS DE ERROR
- REQUISITOS DE INSTALACIÓN
- Instrucciones de instalación
- Preparación de la abertura del gabinete: instalaciones nuevas
- INSTALACIÓN OPCIONAL de la barrera contra la humedad (recomendado para los mostradores de madera)
- CONEXIÓN ELÉCTRICA
- PREPARE LA LAVAVAJILLAS
- Retire el panel de acceso y el aislante
- DESCONECTE Y RETIRE EL ENSAMBLAJE DE LA BANDEJA DE GOTEO
- CONECTE LA TUBERÍA DE AGUA A LA VÁLVULA DE LLENADO
- CONECTE LA MANGUERA DE LLENADO A LA VÁLVULA DE LLENADO
- CONEXIONES DE LA MANGUERA DE DESAGÜE
- Conexión del cable de alimentación
- instale LA MANIJA DE LA PUERTA (EN ALGUNOS MODELOS)
- COLOQUE LA LAVAVAJILLAS EN EL GABINETE
- INSTALACIÓN DEL PANEL A LA MEDIDA (EN MODELOS CON PANELES A LA MEDIDA SOLAMENTE)
- Selección del método de sujeción de anclaje
- VERIFICACIÓN FINAL DE LA INSTALACIÓN
- ASEGURE LA LAVAVAJILLAS EN LA ABERTURA DEL GABINETE
- CONEXIÓN DE TUBERÍA DE AGUA A MANGUERA DE VÁLVULA DE CIERRE DEL HOGAR
- CONECTE LA MANGUERA DE DESAGÜE
- Complete la instalación
- Verifique el funcionamiento
- Instale los paneles de acceso
- si la lavavajillas no funciona
18
DRAIN HOSE CONNECTION
Put provided silver clamp over elbow end of drain hose. Then
push the hose onto the drain port (being sure to push all the way
on) with the hose facing underneath the dishwasher. Using pliers,
squeeze open the drain hose clamp and slide it over the elbow to
ensure the hose is attached in place. Route the hose out of the
back of the product.
NOTE:
■ If the hose is installed with the rubber elbow facing out, the
drain hose may become kinked causing slow or incomplete
draining in tight cabinet installations.
■ There may be a plastic plug in the drain port for shipping
purposes where you will connect the drain hose. Remove
this plug before installing drain hose, if present.
POWER CORD CONNECTION
NOTE: If installing a product with direct wiring, proceed to Step
25, wait to install wiring until after Step 44 when the unit has been
installed in the cabinet opening.
Select UL Listed/CSA Approved power cord for the Dishwasher.
Power Cord Ki
t
Kit typically includes power cord, metallic strain relief,grommet.
(Whirlpool Part Number Cord Kit - Straight - W11365011
Cord Kit - Right Angle - W11365014)
To remove the terminal box, depress the plastic latch, slide the
box toward the left of the unit along the metal tube and rotate the
left side of the box forward. Make sure that the product wiring is
still attached within the terminal box.
Using 1/4" (6.4 mm) nut driver remove the screw holding the
terminal box cover. Remove the cover by lifting it out of the box.
Keep the cover for later use.
Install a UL Listed/CSA Approved metallic strain relief. Make
sure screw heads are facing up when tightening conduit nut.
Strain relief is provided with the power cord kit.
Suggested wire length relative to strain relief
Terminal
box
Drain Hose Location
17. Connect drain hose
18. Remove terminal box
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
19. Remove terminal box cover
Terminal
box cover
20. Install strain relief
4
1
/2"
(114.3 mm)
0.75" - 1"