Service Manual

COMPONENT ACCESS
18” & 24” ADA Built-In Dishwashers
n
4-15
Removing the Thermistor & Turbidity Sensor
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Remove the Thermistor
1. Unplug dishwasher or disconnect power.
2. Open the dishwasher door and take out cutlery basket
and lower rack.
3. Remove dishwasher from installaon and lay dishwasher
on its back.
4. Remove the one (1) screw that aaches base cover to the
base. Remove base cover and set aside.
5. Disconnect the thermistor wire harness (see Figure 1).
6. Using screwdriver remove the two (2) screws securing
thermistor to the sump (see Figure 1). Remove thermistor.
Disconnect Harness
Remove Thermistor
Figure 1
NOTE: Ensure the “0”Ring is retained in the Thermistor before
reassembly.
Remove the Turbidity Switch
1. Unplug dishwasher or disconnect power.
2. Open the dishwasher door and take out cutlery basket
and lower rack.
3. Remove dishwasher from installaon and lay dishwasher
on its back.
4. Remove the one (1) screw that aaches base cover to the
base. Remove base cover and set aside.
5. Disconnect the turbidity sensor wire harness (see Figure
1).
5. Release the snap clips to remove the turbidity sensor from
the dishwasher.
Disconnect Harness
Snap
Clips
Figure 1
NOTE: Ensure the “0”Ring is retained in the turbidity sensor
before reassembly.