Service Manual

4-18
n
18” & 24” ADA Built-In Dishwashers
COMPONENT ACCESS
Removing the Sump Assembly
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Removing the Sump Assembly
Preparation:
Remove the following items from inside the dishwasher (see
Figure 1 below):
1. Cutlery Basket (not shown)
2. Lower Rack (not shown)
3. Lower Spray Arm
4. Cylindrical Filter (1/4 turn counterclockwise)
5. Steel Filter (li out)
6. Lower Spray Seat (see page 4-9)
Figure 1
Lower Spray Arm
Steel Filter
Cylindrical Filter
Connued on next page . . .
Lower Spray Seat
(remove 2 screws)