Service Manual
COMPONENT ACCESS
18” & 24” ADA Built-In Dishwashers
n
4-7
Replace Inner Door Panel
1. Unplug dishwasher or disconnect power.
2. Perform the procedures on page 4-3, “Remove the Control
Panel” prior to performing the following steps.
3. Perform the procedures on page 4-5, “Remove the
Dispenser Assembly” prior to performing the following
steps.
4. Remove the two (2) screws from the hinge plate (as
indicated in Figure 1).
Remove 2 screws from hinge plate
Figure 1
Replacing the Inner Door Panel
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
5. Remove the two (2) screws from the base side panel on
each side (indicated in Figure 2).
Figure 2
6. Disconnect door spring and door cable (see Figure 3).
Door Cable
Door Spring
Figure 3
7. Open the inner door approximately 10° and li the door
unl the door hinge separates from the pin. See Figure 4.
Pin
Figure 4