Installation guide
Gas
Supply
Line
Gas
Pressure
Regulator
m
Provide
a
gas
supply
line
of
%"
(1.9
cm)
rigid
pipe
to
the
cooktop
location.
A
smaller
size
pipe
on
longer
runs
may
result
in
insufficient
gas
supply.
Pipe-joint
compounds
that
resist
the
action
of
LP
gas
must
be
used.
Do
not
use
TEFLON®
tape.
With
LP
gas,
piping
or
tubing
size
should
be
Ya"
minimum.
Usually, LP
gas
suppliers
determine
the
size
and
materials
used
in
the
system.
Flexible
metal
appliance
connector:
m_
lf
local
codes
permit,
use
a
12"
or
%4"
|.D.
flexible
stainless
steel
tubing
gas
connector,
designed
by
CSA
to
connect
the
cooktop
to
the
rigid
gas
supply
line.
gw
A‘%"
male
pipe
thread
is
needed
for
connection
to
the
female
pipe
threads
of
the
inlet
to
the
cooktop
pressure
regulator.
mg
Donot
kink
or
damage
the
flexible
metal
tubing
when
moving
the
cooktop.
Rigid
pipe
connection:
The
rigid
pipe
connection
requires
a
combination
of
pipe
fittings
to
obtain
an
in-line
connection
to
the
cooktop.
The
rigid
pipe
must
be
level
with
the
cooktop
connection.
All
strains
must
be
removed
from
the
supply
and
fuel
lines
so
cooktop
will
be
level
and
in
line.
=
Must
include
a
shutoff
valve:
The
supply
line
must
be
equipped
with
a
manual
shutoff
valve.
This
valve
should
be
located
in
the
same
room
but
external
to
the
cooktop
opening,
such
as
an
adjacent
cabinet.
It
must
be
accessible
without
removing
the
cooktop,
and
it
should
be
in
a
location
that
allows
ease
of
opening
and
closing.
Do
not
block
access
to
shutoff
valve.
The
valve
is
for
turning
on
or
shutting
off
gas
to
the
cooktop.
A.
Gas supply
line
B.
Shutoff
valve
“open”
position
C.
To
cooktop
T®TEFLON
is
a
registered
trademark
of
E.1.
Du Pont
De
Nemours
and
Company.
The
gas
pressure
regulator
supplied
with
this
cooktop
must
be
used.
The
inlet
pressure
to
the
regulator
should
be
as
follows
for
proper
operation:
Natural
Gas:
Minimum
pressure:
5"
(12.7
cm)
WCP
Maximum
pressure:
7"
to
14"
(17.8
cm
to
35.5
cm)
WCP
LP
Gas:
Minimum
pressure:
10”
(25.4
cm)
WCP
Maximum
pressure:
14”
(85.5
cm)
WCP
Contact
local
gas
supplier
if
you
are
not
sure
about
the
inlet
pressure.
Burner
Input
Requirements
Input
ratings
shown
on
the
model/serial
rating plate
are
for
elevations
up
to
2,000
ft
(609.6
m).
For
elevations
above
2,000
ft
(609.6
m),
ratings
should
be
reduced
at
a
rate
of
4%
for
each
1,000
ft
(304.8
m)
above
sea
level
(not
applicable
for
Canada).
Gas
Supply
Pressure
Testing
Gas
supply
pressure
for
testing
regulator
must
be
at
least
1"
water
column
pressure
above
the
manifold
pressure
shown
on
the
model/serial
rating
plate.
Line
pressure
testing
above
‘2
psi
gauge
(14"
WCP)
The
cooktop
and
its
individual
shutoff
valve
must
be
disconnected
from
the
gas
supply
piping
system
during
any
pressure
testing
of
that
system
at
test
pressures
in
excess
of
Ye
psi
(3.5
kPa).
Line
pressure
testing
at
2
psi
gauge
(14"
WCP)
or
lower
The
cooktop
must
be
isolated
from
the
gas
supply
piping
system
by
closing
its
individual
manual
shutoff
valve
during
any
pressure
testing
of
the
gas
supply
piping
system
at
test
pressures
equal
to
or
less
than
¥
psi
(3.5
kPa).