Fix the appliance as follows:
1. Use short flat-bottomed screws to fix the 4 alignment
springs in the holes provided in the centre of each side
of the hob.
2. Insert the hob in the cavity, make sure it is in a central
position and push down on the whole perimeter until the
hob is stuck to the supporting surface.
The screws for the alignment springs must remain
accessible.
In order to adhere to safety standards, the appliance
must not come into contact with electrical parts once it
has been installed.
All parts that ensure the safe operation of the appliance
must not be removable without the aid of a tool.
Electrical connection
The electrical connection of the hob and any built-in
oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
Terminal board
On the lower part of the
appliance there is a connection
box for the different types of
electricity supply (the picture is
only an indication and is not an
exact representation of the
purchased model).
Single-phase connection
The cable provided should only be used for this type of
installation.
Mains supply characteristics:
Voltage and mains frequency
230/240V 1+N ~ 50 Hz
230V 2 ~ 50 Hz
If the hob has a supply cable fitted,
connect it to the mains, using the
colours as a guide (see diagram).
If the hob does not have a supply cable fitted, proceed
as follows:
1. Use the supply cable provided (where applicable) or
a suitable supply cable, H05VV-F or higher, with the right
dimensions (cable section: 2.5 mm).
2. To open the terminal board, insert a screwdriver into
the side tabs of the cover (see Terminal board picture).
3. The terminal board is designed for single-phase
connection: make sure the connection supports between
springs 1 and 2 and those between 4 and 5 are in the
right position (see Single-phase picture).
4. Position the wires according to the following diagram
and table and connect the appliance by tightening all
the screws for the springs as much as possible.
UNDERSIDE OF HOB
5
1
2
3
4
U-bolt
connection support
Phase Neutral Earth
Blue
Brown
N
Neutral
L
Live
Green/Yellow
Earth
Single-phase
5. Secure the power supply cable by fastening the
clamp screw and put the cover back on.
LN
12345
Voltage and
mains
frequency
Electrical connections
Terminal
board
230/240V 1+N ~
50 Hz
230V 2 ~ 50 Hz
Single-