Installation guide

Power Supply Cord Direct Wire
ElectricaB Shock Hazard
Disconnect power before servicing°
Use a new 40 amp power suppmy cord,
Pmug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or emectrical shock,
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or G gauge amuminum wire,
EmectricaHy ground range.
Failure to follow these instructions can resumt in death,
fire, or electricam shock.
1. Disconnect power. 3.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover from range.
'B
Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL listed strain relief in the opening.
j=_ _ .....A
A. UL listed strain relief
Tighten strain relief screw against the power supply cord.
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws