Installation guide

Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
A 4-wire or 3-wire, single phase, 240 volt, 60 Hz., AC only
electrical supply is required on a separate, 40-amp circuit,
fused on both sides of the line.
NOTE: The 15" (38.1 cm) model series requires a 20-amp
circuit.
The cooktop should be connected directly to the junction box
through flexible, armored or nonmetallic sheathed, copper
cable. The flexible, armored cable extending from the fuse box
or circuit breaker box should be connected directly to the
junction box.
Locate the junction box to allow as much slack as possible
between the junction box and the cooktop so that the cooktop
can be moved if servicing becomes necessary in the future.
Do not cut the conduit. Use the length of conduit provided.
A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the
cooktop and at the junction box). A listed conduit connector is
already provided at the cooktop.
If the house has aluminum wiring, connect the aluminum
wiring to the copper wire by using special connectors
designed and UL listed for joining copper to aluminum. Follow
the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
120 volt Cooktop:
Emectrica_ Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or emectrical shock.
A 120 volt, 60 Hz, AC only, 20-amp fuse, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this appliance be provided. A NEMA 5-20R,
3 prong grounding-type outlet must be used.
For your personal safety, this cooktop must be grounded. This
cooktop is equipped with a power supply cord having a NEMA
5-20P, 3 prong grounding plug. To minimize possible shock
hazard, the cord must be plugged into a mating, NEMA 5-20R,
3 prong grounding-type outlet, grounded in accordance with
the National Electrical Code, ANSI/NFPA 70 latest edition, and
local codes and ordinances.
If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have a
properly grounded, NEMA 5-20R, 3 prong outlet installed by a
qualified electrician.
WARNING: Improper connection of the equipment grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or serviceman if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
plug provided with the appliance, if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
1. Remove the shipping materials and tape from the cooktop.
Remove the hardware package from inside the literature bag.
2. Using 2 or more people, place the cooktop upside down on a
protective surface.
E
A. Attachment screw holes for optional front and back location
B. Clamp bracket (end locations recommended)
C. Burner box bottom
D. Attachment screw
E. Attachment screw location (recommended)
Two clamp brackets are provided to clamp the cooktop to the
countertop. Install the clamp brackets on each end of the
burner box bottom. If cabinet construction does not provide
clearance for installing brackets at the burner box ends, install
the brackets on the front and back of the burner box bottom.
NOTE: For lift top models, the brackets may be installed
before or after the cooktop is placed into the cutout. However,
installing the brackets after is not recommended for lift top
models.