Installation
! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future reference.
Pass them on to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can
become a choking or suffocation hazard (see Precautions and tips).
! The appliance must be installed by a qualied professional
according to the instructions provided. Incorrect installation may
cause harm to people and animals or may damage property.
Fitting the appliance
The following precautions must be taken when installing
the hob:
Kitchen cabinets adjacent to the appliance and taller than
the top of the hob must be at least 600 mm from the edge
of the hob.
Hoods must be installed according to their relative
installation instruction manuals and at a minimum
distance of 650 mm from the hob (see gure).
Place the wall cabinets adjacent to the hood at a minimum
height of 420 mm from the hob (see gure).
If the hob is installed beneath a wall
cabinet, the latter must be situated
at a minimum of 700 mm above the
hob (see gure).
The installation cavity should have the dimensions
indicated in the gure. Fastening hooks are provided,
allowing you to fasten the hob to tops that are between 20
and 40 mm thick. To ensure the hob is securely fastened
to the top, we recommend you use all the hooks provided.
555 mm
55 mm
475 mm
Hook fastening diagram
20
30
Hooking position Hooking position
for top H=20mm for top H=30mm
600mm min.
420mm min.
650mm min.
Front
40
Hooking position Back
for top H=40mm
! Use the hooks contained in the “accessory pack”.
Where the hob is not installed over a built-in oven, a wooden
panel must be installed as insulation. This must be placed at
a minimum distance of 20 mm from the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet
must be removed. It is advisable to install the oven so that it
rests on two strips of wood, or on a completely at surface
with an opening of at least 45 x 560 mm (see diagrams).
560 mm.
45 mm.
Where a hob is installed above an oven without a forced
ventilation cooling system, adequate ventilation must be
provided inside the cabinet by means of air holes through
which air can pass (see gure).
Electrical connection
The electric hobs are supplied without power supply
cable since the cable must be sized according to the type
of electrical connection used (see attached connection
diagram). Follow these steps to connect the cable:
Open the terminal box by removing the screws V” and
opening the cover (see gure).
Connect the wires as shown in the diagram.
Fix the cable using the cable clamp F”, replace the cover
and fasten it using the screws “V” (see gure).