Instruction for Use

GB
3
TABLE OF CHARACTERISTSICS
Dimensions
Oven HxDxW
34x39x44
Volume
60 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 18 cm
Voltage and
frequency
see data plate
Electric Hob
Rapid Ø 180 mm: 2000 W
Rapid Ø 145 mm: 1500 W
Max. Hob Power Absorption: 7000 W
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
Static
mode;
This appliance conforms to the following
European Economic Community
directives: 2006/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments - 04/108/EC dated
15/12/04 (Electromagnetic
Compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent amendments.
2002/96/EEC
1275/2008 (Stand-by/ Off mode)
V
Fig. A Fig. B
Connecting the supply cable to the mains
WARNINGS: THIS APPLIANCE MUST BE EARTHED.
Important: The cooker must be connected to the mains by a
switched (double pole) cooker outlet correctly fused with a
capacity appropriate to that shown on the cooker Rating Plate.
All electrical wiring from the consumer unit to the cooker, via the
switched double pole cooker outlet, must be of an acceptable
type and current rating as above.
Note: the supply cable must be positioned so that it never
reaches at any point a temperature 50°C higher than the room
temperature. The cable must be routed away from the rear vents.
700 mm
HOT PARTS
Electrical connection
Electric cookers come without a power supply cable. The
cooker is designed to operate on an electricity supply which
conforms to the electrical data shown on the Rating Plate.
The cooker can be connected to the mains only after removing
the back panel of the cooker itself with a screwdriver.
N.B.: the following installation procedure must be carried out
by a qualified electrician. The electrical installation must
comply with the IEE Regulations, Building & local By-Lays.
For the installation of the feeding cable carry out the following
operations:
z
Unscrew screw “V” (see fig. A)
z
Pull and open the junction blok lid
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow Earth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the terminals
in your plug, proceed as follows:
Green & Yellow wire to terminal marked “E” or
66
66
6
or coloured
Green or Green & Yellow.
Brown wire to terminal marked “L” or coloured Red.
Blue wire to terminal marked “N” or coloured Black (see fig.
B).
z
fix the feeding cable in the special cable stop and close
the cover.
N.B.: the power supply cable must have these minimum
requirements:
Type: H05RR-F
H05VV-F
Section: 3x4 mm
2
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the
places provided on each
corner of the base of the
cooker (
see figure
).
The legs* fit into the slots on
the underside of the base of
the cooker.
IS50ES
IS50E1S
58 l