Instruction for Use

20
GB
B
Assembly: Secure the
activated-carbon lter rst in
the back using the hood's
metal tabs and then in the
front by pressing the two
levers.
Replacing the bulbs
Disconnect the unit from the mains and remove the grease
lter.
Caution! Make sure the bulbs are cool before touching
them.
1. Extract the guard by prising
it out with a small at head
screwdriver or something
similar.
2. Replace the faulty bulb.
Use only bulbs of the
same type (for details,
see the technical data in
the following manual).
3. Re t the guard (push it in).
Electrical cable
If the power cable is damaged, it can be replaced by the
manufacturer or his technical service, to prevent any
attendant risks.
SCRAPPING
The unit is marked for conformity with European Directive
2012/19/EC, Waste Electrical and Electronic Equipment
(WEEE). By ensuring that the unit is scrapped properly,
the user contributes to safeguarding the environment and
public health.
The
symbol on the product or on its accompanying
documents indicates that the product may not be treated
as domestic waste but must be handed over to a sorting
centre for electrical and electronic waste. Dispose of it
in accordance with local waste disposal regulations. For
further information on the handling, recovery and recycling
of this product, contact the local authority, domestic waste
disposal service or the reseller from whom you purchased it
Save energy and respect the environment
Please use the hood by setting the speed in line with the
real extraction need; please limit the use of the “intensive
speed” feature, if present. Using the hood in a rational
way allows you to limit energy consumption and to avoid
an useless waste of clean and air-conditioned air.
Please don’t turn on the hood light unless this is needed
to light the cooking area.
Troubleshooting
If something does not work, make the following simple
checks before contacting Technical Service:
If the hood does not operate:
Check that:
the unit is powered up.
a speed has been set.
If the hood is not working effectively:
Check that:
the selected motor speed is suf cient to handle the
amount of smoke and steam being produced.
the kitchen is adequately ventilated for the unit to take
air in.
• the charcoal lter is not exhausted ( lter version).
If the hood turns off during normal operation:
Check that:
the unit is powered up.
the circuit breaker has not tripped.
In case of faulty operation, before contacting Technical
service, rst disconnect the machine from the mains for at
least 5 seconds by pulling its plug, then reconnect it. If the
fault persist, contact Technical Service.