Installation guide

GASCONVERSIONS
Expmosion Hazard
Use a new AGA or CSA approved gas suppmy mine.
Securety tighten aimgas connections°
if connected to LP, have a quamified person make sure
gas pressure does not exceed 14" (3(} cm) water
comumn.
Exampmes of a qualified person include:
licensed heating personnel,
authorized gas company personnem, and
authorized service personnel
Failure to do so can resumt in death, expmosion, or fire.
Tip Over Hazard
A child or adumt can tip the range and be kiHedo
Connect anti-tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved.
Faimure to follow these instructions can result in death
or serious burns to chimdren and adumts.
To Convert Gas Pressure Regulator
1. Ensure that the manual shutoff valve is in the closed position
and the power supply cord is unplugged.
.......... B
A ]
Remove storage drawer or warming drawer. Locate gas
pressure regulator at rear of storage or warming drawer
compartment.
NOTE: On models with a warming drawer, an access cover
must be removed from the gas pressure regulator.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap (marked "N" on front of gas
pressure regulator) counterclockwise with a wrench to
remove,
NOTE: Do not remove the spring beneath the cap,
B
C
Side view before
D E
Side view after
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn the gas pressure regulator cap over and reinstall on
regulator so that the hollow end faces out and letters "LP" are
visible,
6. Replace plastic cover over gas pressure regulator cap,
A. To range
B. Manual shutoff valve "closed "position
C. Gas supply line
13