[] Insertretractable
downdraftvent intocountertop
cutout.Twopeopleare
recommendedto supportthe
weightof the downdraftvent
duringlifting.Positiondowndraft
ventsoit is centeredin cutoutand
parallelto edgeof cutout.Check
that downdraftventisvertical.Then
attachlowersupportlegstocabinet
floorwith screws.
When attaching undercounter bracket
to underside of countertop, make
sure that the screw length will not go
through countertop when tightened.
1 = Attach one undercounter
mounting bracket on front upper
right corner of downdraft vent
with slot over vent mounting hole
and flange against countertop.
Attach other bracket to left side of
downdraft vent. Carefully drill
starter holes through
undercounter mounting brackets
into underside of countertop.
Insert appropriate length screws
into holes and tighten brackets to
countertop.
Electrical Shock Hazard
Disconnect power before
servicing.
Connect ground wire to green
ground screw in terminal box.
Failure to do so can result in
death or electrical shock.
2 = Disconnect power.
vent box
knockout
\
green
ground
wire ___.
conduit
connector
o
wiring box
cover
teen
screw
[] Feed the power supply
cable through the conduit
connector and into wiring box.
Connect the white wires together
with a twist-on wire connector.
Connect the black wires together
with a twist-on wire connector.
Attach the green (or green and
yellow) ground wire to eyelet with
green ground screw and tighten
screw. Replace wiring box cover.
green
screw
ground
wire
-_//_" ext eric r-too u nt ed
vent motor wiring
I 4= Remove vent box
knockout and install conduit
connector.
Feed exterior-mounted vent motor
wiring through conduit connector.
IMPORTANT: Do not wire the
exterior vent motor black and
white wires into the wiring box.
Wires must be connected as
shown. Connect the white wires
together with a twist-on wire
connector. Connect the black
wires together with a twist-on
connector.
Attach ground wire to eyelet with
green ground screw and tighten
screw.
Tighten conduit connector clamp
screws.
15= Reconnect power.
microswitches behind filters
ON/OFF
lower
ontrol
_filter or filters
depending on _ X
model end cap
6_ Push and hold for a few
seconds the button on the top of
the downdraft vent. Retractable
section of downdraft vent will rise
and blower will start. Position the
top trim over the retractable
section and snap trim into place.
7= Turn the control knob on
side of vent to check the
operation and speed of blower.
If blower does not operate:
Check that filter or filters are
pressed in as far as they will go.
Check that circuit breaker is not
tripped or house fuse blown.
Reconnect power. Check that
wire connections have been
made correctly.
I 8[] Connect vent to blower.
Position vent to avoid wall studs
and floor joists. Complete all vent
work. Use duct tape to sealall
joints. Vertical vent for wall-
mounted installations should pitch
down slightly toward the vent to
allow moisture to run outside.
9= Install cooktop according
to manufacturer's instructions,
Check that rear of cooktop overlaps
edge of retractable downdraft vent
by 3/8" (9.5 mm).
To get the most efficient
use from your new
retractable downdraft vent,
read the Use and Care
Information section on
page 12.
Keep Installation Instructions
and Use and Care
Information close by for
easy reference.
11