Instruction for Use

20
GB
Table of burner and nozzle specifications
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Heating
power kW
(H.s.*)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Flow rate *
g/h
Nozzle
1/100
(mm)
Flow
rate *
l/h
Nomin. Red. G30 G31 G20
C. Rapid
100 3.00 0.7 40 86 218 214 116 286
B. Semi-rapid 75 1.65 0.4 30 64 120 118 96 157
A. Auxiliary
55 1.00 0.4 30 50 73 71 71 95
D. Triple ring 130 3.25 1.3 57 91 236 232 124 309
Supply pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m
3
TABLE OF CHARACTERISTICS
Oven dimensions
(HxWxD)
32x43.5x40 cm
Volume lt. 56
Burners
may be adapted for use with any
type of gas shown on the data
plate
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
Declared energy consumption for
Forced convection Class
heating mode: Gratin.
EC Directives: 2006/95/EEC dated
12.12.06 (Low Voltage) and
subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments -
90/369/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.