Instruction for Use
AKT 305 IX PRODUCT DESCRIPTION SHEET
GB
5019 319 62039/A
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
ITPT ES GB
LIGHTING THE BURNERS
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
• The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1.
Removable pan grid
2.
4 rings burner
3.
4 rings burner knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
4 rings burner
from 24 to 26 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V - 50 Hz
Type of gas used Type of burner Ø injector Rated thermal
flow rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
4 ring 139 3.50 333 l/h 1.50 17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
4 ring 95 3.50 254 g/h 1.50 20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
4 ring 95 3.50 250 g/h 1.50 25 37 45
Type of gas
used
Configuration
model
Rated thermal
flow rate kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 1 burner 3.50 333 l/h 9.52
G30 28-30 mbar 1 burner 3.50 254 g/h 30.94
G31 37 mbar 1 burner 3.50 250 g/h 23.8