Instruction for Use

GB11
- use protective gloves.
- disconnect the appliance from the power supply.
GREASE FILTERS
The metal grease filter has an unlimited life and should be cleaned once a month by hand or in a
dishwasher at low temperature and with a short cycle. Cleaning in a dishwasher may cause discoloring of
the grease filter, but its filtering efficiency is unaffected.
Pull out the handle to remove the filter.
Wash the filter and leave it to dry, proceeding in reverse order to refit.
REPLACING HALOGEN LAMPS
IMPORTANT: Only use halogen lamps 28W MAX - E14.
1. Disconnect the hood from the household power supply.
2. Remove the grease filters.
3. Remove the burnt-out lamp by unscrewing it from the lamp holder and fit a new one.
4. Refit the grease filters.
ACTIVATED CARBON FILTER
(filter hoods only):
It retains the unpleasant odors produced during cooking.
Change the carbon filter every 4 months.
Fitting or changing the carbon filter
1. Disconnect the hood from the power supply.
2. Remove the grease filters.
3. Fit the filters over the motor.
Make sure the pins R on the manifold match the slots S; turn the filters to secure them to the pins.
Proceed in reverse order to remove.
Refit the grease filters.
ATTENTION:
R
R
R
S
S
S
S
MAINTENANCE