INSTALLATION - ASSEMBLY INSTRUCTIONS
The instructions below, to be carried out in the order in which they are numbered, refer to the gures (with the same step numbers) given on the last pages of
this manual.
1. Prepare the cut-out on the back of the wall unit, corresponding to the overall dimensions of the hood
60 cm = 260X493
90 cm = 260X693
2. Prepare the hole at the top for the exhaust pipe Ø150
3. Fit the exhaust pipe connector (using the two 3.5x9.5 screws provided)
4. Remove the protective lm from the lateral adhesive strips
5. Slide the hood inside the wall unit
6. The lateral snap-in supports will return to the outside, allowing to fasten the hood to the wall unit
7. Secure the xing by tting n°.4 screws (two each side) to each side support:
16mm screw, for wall units 15 to 20mm thick,
12mm screw for wall unit above 20mm thick
Note: when fastening, apply a light pressure on the hood body, in order to facilitate the lateral adhesive gripping
8. Fit n°.4 screw caps
9. Connect the hose (to be purchased separately) for venting the exhaust fumes; if necessary, use the multi-connection ange to reduce the aperture to
ø125-120
For Extractor Version only: feed the hose towards the exterior
For lter versions only: t the ow-diverter grille (to be purchased separately) to the top of the of the wall unit
10. Open the perimeter extraction panel and remove the grease lter,
11. For lter version only: insert the carbon lters (refer to instructions in the section MAINTENANCE-Carbon Filter)
12. Ret the grease lter
13. Close the perimeter extraction panel