E030101CW 23/11/04
cooling down by draining warm water down to 10
cms level, loading then cold water up to 25 cms,
keeping temp. alteration under control within a
range of 5° C cooling per minute.
TEMPERATURE: is end step (in ° C)
EXAMPLE 1: heating step for temperature
parameter of 90° C elements will heat up to above
90°C
EXAMPLE 2: cooling step for temperature
parameter of 30°C, cooling will keep on until
water temp. will be under 30°C
Time is end step in seconds.
EXAMPLE 1: loading step for detergent 1;
parameter is time, 30 seconds: detergent will be
loaded for 30 secs
EXAMPLE 2: step is spin duration, parameter
is time 5 mins.: spinning will last 5 mins.
WDT: watch-dog time= max. allowed time to
complete step (in minutes) example: loading step
has level parameter in 15 cms. of water with 30
mins. WDT. 15 cms of water will be loaded within
30 mins., if not, alarm will ring.
PLEASE NOTE that during programming, some
parameters may not appear if they are not
compatible to the related step (i.e. in a step of
spinning duration, temperature does not appear).
23.MOTOR TYPES
Motor Type is a step parameter; motor types
available are 16, identified by numbering: 1,2,3,4,
and so on. First 4 are factory-stored in the
microprocessor (see § 30) and may anyway be
modified. Motor types are free from 5 to 15
MOTOR TYPE NO. Main specs composing Motor
Type are: clockwise and
Anti-clockwise rotation (in seconds), interval time.
Motor type “NO” does not have rotations times. If
selected, the motor does not turn for all the step.
PLS NOTE that not all steps have motor as a
parameter. For instance linen distribution and
spinning only turn clockwise.
24. SET-UP/MODIFICATION OF MOTOR TYPES
Modifying a motor type means modifying rotation
and interval times in a step parameter. PLEASE
NOTE that when modifying a motor type, all
programmes containing that motor type will be
affected.
Example: set-up/modification of motor type 5 to
consist of: 20 secs clockwise rotation, 10 secs
interval, 20 secs anti-clockwise rotation.
To enter programming, open door, display shows
“DOOR OPEN”, press “MENU”, display shows
“PASSWORD”, press 6 times on “START”.
Display shows “SET-UP/MODIFY
PROGRAMMES”. Use “+” & “-“ to scroll main
menu, until display shows “SET-UP/MODIFY
MOTOR TYPE” . Press “ENTER”, display shows
“MOTOR TYPE 1”. Use “+” & “-“ to scroll motor
types until display shows “MOTOR TYPE 5” ,
press “ENTER” to select. Use “+” & “-“ to scroll
motor types parameters. To modify a parameter
value press “ENTER” and use “+” & “-“ to increase
or decrease. In this motor type, modify
parameters as per example: FORWARD (20
secs.) INTERVAL (10 secs), BACKWARDS (20
secs.). When all parameters are programmed,
press “MENU” more times to scroll upwards to
other menus.
25. LANGUAGE SWITCH
Our microprocessori s set up in several
languages. To select a language, pls open door “,
display shows “DOOR OPEN”, press “MENU”,
display shows “PASSWORD”, press 6 times on
“START”, display shows “ PROGRAMMES SET-
UP/MODIFICATION. Use “+” & “-“ to scroll main
menu until display shows “LINGUA”. Press
“ENTER” to select. Use “+” & “-“ to choose
available languages and “ENTER” to confirm
language choice. Press “MENU” more times to
scroll upwards to other menus.
26. CONNECTION TO PERSONAL COMPUTER
Wizard software may connect your PC to our
micorprocessor. In this case washer must be
equipped with serial gate RS232 (9 pins –
optional) to be connected by means of a cable (as
option) with following specs:
- 3 strand cable with net
- 9 pins serial gate RS 232 –female plugs
on both cable ends
- designation as A & B for cable ends
connect pin 2 on end A to pin 3 on B
connect pin 3A to 2B
connect pin 5A to 5B
make a connection among the pin 1,4,6
and anothe one among the pin 7,8
connect cable-net to 5A
Directions for usage of Wizard are included in
“HELP” of its software
27. MODEM COMMUNICATION
Some washing machine models are equipped with
modem. This instrument allows the
communication, with non mobile telephone
connection, between the microprocessor IM6 and
a remote PC. On remote PC install the modem
driver following the instruction of “Rapid Guide”,
supplied with the machine.
The connection on the machine must be carried
out as follow:
- turn off the machine through the general
main switch
- make a bridge between the modem serial
29