This tester was designed according to EN71-2008 standard, both sell to overseas and
dometic market.
(1) Adopt the mininsize gas cylinder system, the instrument can be moved, take up
small space. The user also can connect big gas cylinder.
(2) The gas system is controlled by PLC, ignite and continue burning time are
accuracy,
(3) All frames can be adjusted to meet different testing need.
This instrument applies to test the performance of flame retardardant of toys for
children, completely applies to EN71-2-2008.
Main technical parameters
1、Ignition time set range:0~99.99S Precision:0.01S
2、continue burning time range :0-999.9S precision0.1S
3、Please put this flammability into a cabinet to make test.
4、Ignition mouth size: applies to IS0 6941 standard.
5、Dimension of specimen: 150mmX560mm
6、Power: AC200V 50Hz
7. Weight:40KG
8 Gas: butane gas。
9 Thread: white cotton thread.
Gas Device
Control Panel