Dimension Sheet

Dimension and installation guide
© 2020 Electrolux Home Products Pty Ltd. ABN 51 004 762 341. WDIM_Aspire_Apr20
IMPORTANT
These dimensions are a guide only. All measurements are in millimetres (mm).
For complete installation instructions, refer to the manual provided with product.
westinghouse.com.au
Built in microwaves
WMB4425SC, WMB4425DSC
Product WxHxD (mm) 596 x 454 x 568
Flush mount cut-out WxHxD (mm) 600 x 466 x 570
15INSTALLATION
WARNING
CAUTION
Do not block the air vents. If you do that, the appliance
can overheat.
WARNING
CAUTION
Do not connect the appliance to adapters or extension
leads. This can cause overloading and risk of fire.
Model WMB4425DSC is for built-in use only.
The fitted cabinet must not have a back wall behind
the appliance.
Put the appliance far away from steam, hot air and
water splashes.
If the appliance is stored/ transported at sub-zero
temperatures, do not activate it immediately after
installation. Allow at least two hours for it to be brought
up to room temperature before turning on the unit.
Installation - Built-in model WMB4425DSC
For the best integration within a kitchen, install this
appliance in a standard 600mm wide cupboard that gives
a flush fit with the surrounding cupboard fronts. A recess
of 20mm is ideal.
The built-in cabinet must not have a rear wall behind
the appliance. Do not cover ventilation slots and air
intake points.
NOTE: Your appliance must be mounted on a flat surface
for the full width and depth of the product.
Built-in furniture flush fit
600mm
466mm
(+6)
Min.
570mm
45mm
Min airflow gap
at front 50mm
3
A 45mm ventilation gap must be left between the built-in
cabinetry and wall with no back panelling on the cabinet
housing the microwave oven. A minimum ventilation gap
of 3.5mm must be left between the bottom of the front
trim and adjacent shelf/cupboard.
Failure to accommodate for this gap in the installation
can cause product malfunctions which are not covered
under warranty
Side view
45mm
6mm packer
Please note
packer must be
set back 20mm
from front trim to
avoid obstruction
of front vent.
Packer must be
secured to base
of cabinet.
microwave
oven
20mm
External face
of cabinet
and/or door
Min 3.5mm
ventilation
gap below
trim
Min airflow gap
at front 50mm
3
Flush fit top view
infill panel
350mm max. length
20mm
600mm
Cupboard
door
Cupboard
door
Infill panels are recessed 20mm from the external cabinet
door to accommodate flush fit.
INSTALLATION
568
454
596
570
600
466