User Manual
25
GB
For your safety
Warning! Fire and explosion hazard!
Hot tools represent a fi re hazard
Always place the soldering tool in the safety rest while not in use.
Do not place or leave the hot soldering or desoldering tip on the worktop or on plastic surfaces.
Avoid unintentional operation. Disconnect the soldering tool from the power supply while not in
use
.
Do not direct hot air soldering tools at people or inflammable
objects.
Keep explosive and fla
mmable objects well away from the device.
Do not cover the device.
Specified Conditions Of Use
Use the soldering / desoldering iron exclusively for
the purpose indicated in the operating instructions
of releasing, accommodating and depositing elec-
tronic components under the conditions specifi ed
herein.
WXDP 120 (Robust), WXDV 120
Flammable gases and liquids may not
be extracted.
The device may only be used with cor-
rectly fi tted and suitable fi lter cartridges.
Replace fi lter cartridges when full.
Intended use of the soldering station/ desoldering
station also includes the requirement that you
adhere to these instructions,
observe all other accompanying documents,
comply with national accident prevention
guidelines applicable at the place of use.
The manufacturer will not be liable for unautho-
rised modifi
cations to the device.
User groups
Due to differing degrees of risk and potential hazards, several work steps may only be performed by
trained experts.
Work step User groups
Replacing electrical replacement parts Electricians
Default maintenance intervals Safety expert
Operation
Filter change
Non-specialists
Operation
Filter change
Replacing electrical replacement parts
Technical trainees under the guidance and supervision
of a trained expert