Brochure/Catalogue
C
C.16 2028840000
Lightning and surge protection
for low voltage supply
Type I and II lightning arrester
• Pluggable arrester
• Suitable with 25 kA (10/350 µs) for protective level I, II,
III and IV (LPL I/II/III/IV)
• Tested according to IEC 61643-11 for Type I and II surge
protection
• Can also be used as Type II surge protection
• Field of application downstream of the main electrical
meter
Technical data
Rated voltage (AC)
Max. continuous voltage, Uc (AC)
Lightning test current Iimp (10/350 µs) [L-PE]
Discharge current I
n
(8/20µs) wire-PE
Discharge current I
max
(8/20µs) wire-PE
Requirements class, acc. to EN 61643-11
Short-circuit current rating I
SCCR
Leakage current at U
n
Rated load current I
L
Fuse
Temporary surge voltage (over-voltage) - TOV
Protection level with I
N
(L/N-PE)
Response time
Optical function display
Design
Colour
Ambient temperature (operational)
Storage temperature
Connection according to IEC 947-7-1
Solid
Stranded
Stripping length
Tightening torque
Approvals
Approvals
Standards
Dimensions / Signalling contact info
Clamping range (nominal / min. / max.) mm²
Height x width x depth mm
Signalling contact
Note
Ordering data
without remote signalling contact
with remote signalling contact (R)
Note
Accessories
Note
VPU I 3/R 280 V / 25 kA
/
2. 2.
&+$1*(
/
/
8
&+$1*(
/
/
8
2.
&+$1*(
/
8
3(13(1
230 V
280 V
25 kA
25 kA
100 kA
T1, T2
25 kA
30 µA
100 A
250 A gL (if mains > 250 A)
438 V
≤ 1.4 kV
≤ 25 ns
green = OK; red = arrester is defective - replace
Installation housing; 6 TE, Insta IP 20
Black, Arrester red
-40 °C...70 °C
-40 °C...80 °C
4...16 mm²
2.5...50 mm²
15 mm
2...3 Nm
IEC61643-11, EN61643-11
no remote sig. contact with remote signalling (R)
16 / 4 / 25 16 / 4 / 25
94 / 106.8 / 69 106 / 106.8 / 69
250 V 1A 1CO
Type Qty. Order No.
VPU I 3 280V/25KA 1 2062940000
VPU I 3 R 280V/25KA 1 2062910000
Pluggable spare arrester VPU I 0 280 V/25 kA-2067650000
VPU I 4/R 280 V / 25 kA
/
2. 2.
&+$1*(
/
/
8
&+$1*(
/
/
8
2.
&+$1*(
/
3(
8
2.
1
&+$1*(
1
3(
8
230 V
280 V
25 kA
25 kA
100 kA
T1, T2
25 kA
30 µA
100 A
250 A gL (if mains > 250 A)
438 V
≤ 1.4 kV
≤ 25 ns
green = OK; red = arrester is defective - replace
Installation housing; 8 TE, Insta IP 20
Black, Arrester red
-40 °C...70 °C
-40 °C...80 °C
4...16 mm²
2.5...50 mm²
15 mm
2...3 Nm
IEC61643-11, EN61643-11
no remote sig. contact with remote signalling (R)
16 / 4 / 25 16 / 4 / 25
94 / 142.4 / 69 106 / 142.4 / 69
No 250 V 1A 1CO
Type Qty. Order No.
VPU I 4 280V/25KA 1 2062960000
VPU I 4 R 280V/25KA 1 2062950000
Pluggable spare arrester VPU I 0 280 V/25 kA-2067650000
Type I and II lightning arrester