Brochure/Catalogue
Klippon
®
TB QL – Quarter Lock
Technical Overview
Technical data
Enclosure material* Stainless steel 1.4404 (316L) 1.5 mm
Surface nish Electropolished
IP protection class IP66 to IEC EN 60079-0
NEMA protection classes 3, 4x, 12
Gland plates 1 - 4 (xed with M6 hexagon head screws and 10 mm heads), optionally without a gland plate
Gland plate thickness 3 mm (other thickness of up to 20 mm are available on request)
Earthing inside Enclosure base and lid: welded M6 stainless steel earth studs
Earthing outside Continuous M10 brass earth stud (optionally with stainless-steel earth stud)
Installation mounting 4 or 9 mounting bolts with M6 threaded holes to attach the mounting plate or mounting rails
Enclosure attachment 4 or 6 welded mounting feet with 11-mm holes (2 slotted and 2 cross-shaped openings)
Lid opening Can be removed completely, lid opening angle 130 °
Cover attachment Quarter-turn lock with slotted insert (other inserts available on request)
Impact resistance 7 J in accordance with IEC 60079-0, IK 09 (10J) in accordance with DIN EN 50102
Gasket material Silicone
Operating temperature range -60 °C...+135 °C
Torque for ange plate screws 2.5 Nm
Note * Painted steel enclosures are available on request.
Approvals for empty enclosures
ATEX certicate IBExU14ATEX1028 U EAC RU-DE.08.B.00472
ATEX marking II 2G Ex eb llC Gb
cULus E243298
II 2D Ex tb lllC Db
DNV GL TAE000013S
IECEx certicate IECEx IBE 14.0004U Russian Maritime Register 15.40075.250
IECEx marking Ex eb IIC Gb
CCOE In preparation
Ex tb IIIC Db
INMETRO IEx 17.0020U
Nepsi Ex certicate GYJ14.1308U AEx E223792
Nepsi Ex marking Ex e IIC Gb, DIP A21 Miscellaneous EN 45545, DIN EN 15085-2/CL2
Note The Klippon
®
TB enclosure range can be pre-tted in our customer specic production department according to your wishes.
Approvals for control and distribution box
ATEX certicate IBExU14ATEX1050 IECEx certicate IECEx IBE 14.0013
ATEX marking
T II 2G Ex eb IIC/IIB/IIA T6/T5/T4 Gb
IECEx marking Ex eb IIC/IIB/IIA T6/T5/T4 Gb
T II 1G Ex ia IIC/IIB/IIA T6/T5/T4 Ga
Ex ia IIC/IIB/IIA T6/T5/T4 Ga
T II 2G Ex eb ia IIC/IIB/IIA T6/T5/T4 Gb
Ex eb ia IIC/IIB/IIA T6/T5/T4 Gb
T II 2D Ex tb IIIC T80°C/T95°C/T135°C Db
Ex tb IIIC T80°C/T95°C/T135°C Db
T II 1D Ex ia IIIC T80°C/T95°C/T135°C Da
Ex ia IIIC T80°C/T95°C/T135°C Da
-60 °C ≤ Ta ≤ +40/+55/+90 °C -60 °C...+40/+55/+90 °C
Nepsi Ex certicate GYJ14.1309 INMETRO certicate IEx 17.0021
Nepsi marking Ex e IIC T4...T6 Gb INMETRO marking Ex eb IIC T6/T5/T4 Gb
Ex ia IIC T4...T6 Ga Ex ia IIC T6/T5/T4 Ga
Ex e ia IIC T4...T6 Gb Ex eb ia IIC T6/T5/T4 Gb
DIP A21 T
A
85°C...T
A
135°C Ex tb IIIC 85°C/100°C/135°C Db IP66/IP67
Ex ia D20 T85 °C... T135 °C Ex ia IIIC 85°C/100°C/135°C Da
EAC certicate RUC-DE.08.B.01328 AEx certicate E223792
EAC marking II 2 G Ex eb IIC T6...T4 AEx marking Class I, Zone 1, AEx e IIC Gb T6..T4
II 2 G Ex e IIC T6...T4 Gb Class I, Zone 2, AEx e IIC Gc T6..T4
II 1 G Ex ia IIC T6...T4 Class I Div.2 Group A,B,C,D T6…T4
II 1 G Ex ia IIC T6...T4 Ga Class II Div.2 Group F,G
II 2(1) G Ex eb ia IIC T6...T4 Zone 21, AEx tb IIIC Db
II 2(1) G Ex e ia IIC T6...T4 Gb
II 2 D Ex tb IIIC T85°C...T135°C
II 2 D Ex tb IIIC T85°C...T135°C Db
KOSHA certicate 16-AV4BO-0245X
KOSHA marking Ex eb IIC/IIB/IIA T6/T5/T4 Gb
Ex ia IIC/IIB/IIA T6/T5/T4 Ga
Ex eb ia IIC/IIB/IIA T6/T5/T4 Gb
Ex tb IIIC T80°C/T95°C/T135°C Db
Ex ia IIIC T80°C/T95°C/T135°C Da
-60 °C...+40/+55/+90 ° C
Note Labelling depends on the application layout. For details of power dissipation, please contact your Weidmüller representative. Additional approvals available on request.
C
C.392712630000
Enclosures