Brochure/Catalogue
D
Cable entries
D.32 2712630000
Klippon
®
cable glands – Nickel–plated Brass – Ex e, Ex d, IP66 / IP68 for armoured cables
/
'
/
'
6:
Cable gland for cables and lines with braided armouring.
Technical data
Material Brass, nickel-plated
Seal insert Silicone
Temperature range -60 °C...180 °C
Protection class IP54
Protection degree with GWDR IP66, IP68 - 2.5 bar
Water depth 25 m (30 Min.)
Type of armouring Braided armouring
Marking ATEX: II 2G, Ex db IIC Gb, Ex eb IIC Gb, II 1D, Ex ta IIIC Da, IECEx: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
Certificate no. (ATEX / IECEx / EAC) SIRA 05ATEX1286X / IECEx SIR 05.0067X / RUC-DE.IT08.B.00594
Note
Length "L" depends on the cable diameter used. IP protection without GWDR is IP54. To achieve IP66 / IP68 protection, a nylon GWDR must be ordered separately. Cable glands made of brass with
natural surface are available in the online catalogue (catalog.weidmueller.com).
Ordering data
Type Thread D1 outer cable Ø D2 inner cable Ø Cable armour L/L1 SW SUHB Qty. Order No.
metric, nickel-plated brass
KDSX M20 BS O NI 1 G16 M 20 4.9-10.3 3.50-8.40 0.15-0.35 58 / 16 24 L24 20 1135910000
KDSX M20 BS O NI 2 G16 M 20 8.4-13.5 3.50-8.40 0.15-0.35 58 / 16 24 L24 20 1135920000
KDSX M20 BS O NI 1 G20 M 20 12-17.6 9.30-14.00 0.15-0.5 58 / 16 30 L30 20 1135950000
KDSX M20 BS O NI 2 G20 M 20 15.5-21.1 9.30-14.00 0.15-0.5 58 / 16 30 L30 20 1135960000
KDSX M20 BS O NI 1 G20S M 20 9.4-12.5 8.00-11.70 0.15-0.35 58 / 16 24 L24 20 1135930000
KDSX M20 BS O NI 2 G20S M 20 11.5-16 8.00-11.70 0.15-0.35 58 / 16 24 L24 20 1135940000
KDSX M25 BS O NI 1 G25 M 25 16.8-23.9 13.00-20.00 0.15-0.5 58 / 16 38 L38 20 1135970000
KDSX M25 BS O NI 2 G25 M 25 20.3-27.4 13.00-20.00 0.15-0.5 58 / 16 38 L38 20 1135980000
KDSX M32 BS O NI 1 G32 M 32 23.2-30.5 19.00-26.30 0.15-0.55 65 / 16 46 L46 10 1135990000
KDSX M32 BS O NI 2 G32 M 32 26.7-34 19.00-26.30 0.15-0.55 65 / 16 46 L46 10 1136000000
KDSX M40 BS O NI 1 G40 M 40 28.6-36.2 25.00-32.20 0.2-0.6 72 / 16 55 L55 10 1136010000
KDSX M40 BS O NI 2 G40 M 40 33-40.6 25.00-32.20 0.2-0.6 72 / 16 55 L55 10 1136020000
KDSX M50 BS O NI 1 G50 M 50 41.1-48.5 36.50-44.10 0.5-0.8 73 / 16 65 L65 1 1136050000
KDSX M50 BS O NI 2 G50 M 50 45.7-53.2 36.50-44.10 0.5-0.8 73 / 16 65 L65 1 1136060000
KDSX M50 BS O NI 1 G50S M 50 34.8-42.4 31.50-38.20 0.2-0.6 73 / 16 65 L65 1 1136030000
KDSX M50 BS O NI 2 G50S M 50 39.4-46.7 31.50-38.20 0.2-0.6 73 / 16 65 L65 1 1136040000
KDSX M63 BS O NI 1 G63 M 63 53.8-61.2 49.50-56.00 0.5-0.8 76 / 19 80 L80 1 1136090000
KDSX M63 BS O NI 2 G63 M 63 58.4-65.8 49.50-56.00 0.5-0.8 76 / 19 80 L80 1 1136110000
KDSX M63 BS O NI 1 G63S M 63 47.5-54.8 42.50-50.10 0.5-0.8 76 / 19 80 L80 1 1136070000
KDSX M63 BS O NI 2 G63S M 63 52.1-59.5 42.50-50.10 0.5-0.8 76 / 19 80 L80 1 1136080000
KDSX M75 BS O NI 1 G75 M 75 66.5-73.4 60.50-68.00 0.5-1 82 / 19 90 L90 1 1136140000
KDSX M75 BS O NI 2 G75 M 75 71.1-78 60.50-68.00 0.5-1 82 / 19 90 L90 1 1136150000
KDSX M75 BS O NI 1 G75S M 75 60.2-68 54.50-62.00 0.5-1 82 / 19 90 L90 1 1136120000
KDSX M75 BS O NI 2 G75S M 75 64.8-72.2 54.50-62.00 0.5-1 82 / 19 90 L90 1 1136130000
Note
• All cable glands have a thread pitch of 1.5mm.
• In the case of Ex d applications, the inner threads used for cable glands must meet the requirements of section 5.3 of EN/IEC 60079-1. In the screwed in position, at least 5 threads must be engaged.
• If the cable glands are installed in non-metallic Ex e connection equipment, these must be connected to the protective earth of the system.
• The connection cable must be laid securely and inflexibly to rule out tensile stress.
• Installation specifications and tightening torques can be found in the installation instructions. For further information please use our online catalogue: catalog.weidmueller.com.
Ex-cable glands – Brass