Brochure/Catalogue

D
Cable entries
D.32 2712630000
Klippon
®
cable glands – Nickel–plated Brass – Ex e, Ex d, IP66 / IP68 for armoured cables
/
'
/
'
6:
Cable gland for cables and lines with braided armouring.
Technical data
Material Brass, nickel-plated
Seal insert Silicone
Temperature range -60 °C...180 °C
Protection class IP54
Protection degree with GWDR IP66, IP68 - 2.5 bar
Water depth 25 m (30 Min.)
Type of armouring Braided armouring
Marking ATEX: II 2G, Ex db IIC Gb, Ex eb IIC Gb, II 1D, Ex ta IIIC Da, IECEx: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
Certificate no. (ATEX / IECEx / EAC) SIRA 05ATEX1286X / IECEx SIR 05.0067X / RUC-DE.IT08.B.00594
Note
Length "L" depends on the cable diameter used. IP protection without GWDR is IP54. To achieve IP66 / IP68 protection, a nylon GWDR must be ordered separately. Cable glands made of brass with
natural surface are available in the online catalogue (catalog.weidmueller.com).
Ordering data
Type Thread D1 outer cable Ø D2 inner cable Ø Cable armour L/L1 SW SUHB Qty. Order No.
metric, nickel-plated brass
KDSX M20 BS O NI 1 G16 M 20 4.9-10.3 3.50-8.40 0.15-0.35 58 / 16 24 L24 20 1135910000
KDSX M20 BS O NI 2 G16 M 20 8.4-13.5 3.50-8.40 0.15-0.35 58 / 16 24 L24 20 1135920000
KDSX M20 BS O NI 1 G20 M 20 12-17.6 9.30-14.00 0.15-0.5 58 / 16 30 L30 20 1135950000
KDSX M20 BS O NI 2 G20 M 20 15.5-21.1 9.30-14.00 0.15-0.5 58 / 16 30 L30 20 1135960000
KDSX M20 BS O NI 1 G20S M 20 9.4-12.5 8.00-11.70 0.15-0.35 58 / 16 24 L24 20 1135930000
KDSX M20 BS O NI 2 G20S M 20 11.5-16 8.00-11.70 0.15-0.35 58 / 16 24 L24 20 1135940000
KDSX M25 BS O NI 1 G25 M 25 16.8-23.9 13.00-20.00 0.15-0.5 58 / 16 38 L38 20 1135970000
KDSX M25 BS O NI 2 G25 M 25 20.3-27.4 13.00-20.00 0.15-0.5 58 / 16 38 L38 20 1135980000
KDSX M32 BS O NI 1 G32 M 32 23.2-30.5 19.00-26.30 0.15-0.55 65 / 16 46 L46 10 1135990000
KDSX M32 BS O NI 2 G32 M 32 26.7-34 19.00-26.30 0.15-0.55 65 / 16 46 L46 10 1136000000
KDSX M40 BS O NI 1 G40 M 40 28.6-36.2 25.00-32.20 0.2-0.6 72 / 16 55 L55 10 1136010000
KDSX M40 BS O NI 2 G40 M 40 33-40.6 25.00-32.20 0.2-0.6 72 / 16 55 L55 10 1136020000
KDSX M50 BS O NI 1 G50 M 50 41.1-48.5 36.50-44.10 0.5-0.8 73 / 16 65 L65 1 1136050000
KDSX M50 BS O NI 2 G50 M 50 45.7-53.2 36.50-44.10 0.5-0.8 73 / 16 65 L65 1 1136060000
KDSX M50 BS O NI 1 G50S M 50 34.8-42.4 31.50-38.20 0.2-0.6 73 / 16 65 L65 1 1136030000
KDSX M50 BS O NI 2 G50S M 50 39.4-46.7 31.50-38.20 0.2-0.6 73 / 16 65 L65 1 1136040000
KDSX M63 BS O NI 1 G63 M 63 53.8-61.2 49.50-56.00 0.5-0.8 76 / 19 80 L80 1 1136090000
KDSX M63 BS O NI 2 G63 M 63 58.4-65.8 49.50-56.00 0.5-0.8 76 / 19 80 L80 1 1136110000
KDSX M63 BS O NI 1 G63S M 63 47.5-54.8 42.50-50.10 0.5-0.8 76 / 19 80 L80 1 1136070000
KDSX M63 BS O NI 2 G63S M 63 52.1-59.5 42.50-50.10 0.5-0.8 76 / 19 80 L80 1 1136080000
KDSX M75 BS O NI 1 G75 M 75 66.5-73.4 60.50-68.00 0.5-1 82 / 19 90 L90 1 1136140000
KDSX M75 BS O NI 2 G75 M 75 71.1-78 60.50-68.00 0.5-1 82 / 19 90 L90 1 1136150000
KDSX M75 BS O NI 1 G75S M 75 60.2-68 54.50-62.00 0.5-1 82 / 19 90 L90 1 1136120000
KDSX M75 BS O NI 2 G75S M 75 64.8-72.2 54.50-62.00 0.5-1 82 / 19 90 L90 1 1136130000
Note
All cable glands have a thread pitch of 1.5mm.
In the case of Ex d applications, the inner threads used for cable glands must meet the requirements of section 5.3 of EN/IEC 60079-1. In the screwed in position, at least 5 threads must be engaged.
If the cable glands are installed in non-metallic Ex e connection equipment, these must be connected to the protective earth of the system.
The connection cable must be laid securely and inflexibly to rule out tensile stress.
Installation specifications and tightening torques can be found in the installation instructions. For further information please use our online catalogue: catalog.weidmueller.com.
Ex-cable glands – Brass